Specifications
AD 512
12-5
BaseAddress - Enter the base address of the board. This entry must
correspond to the jumper settings on the board. For example, if the base
address is 300 (hexadecimal), enter
0x300
AD 512 Analog Output (D/A)
Scaling Input to Output
Driver Block Parameters
Channel Vector - This parameter is a combined Channel Vector and Range
Vector. The number of elements defines the number of D/A channels used.
Enter a range code for each of the channels used. This driver allows a different
range for each channel with a maximum of 2 channels.
The following table is a list of the ranges for this driver and the corresponding
range codes.
For example, if the first channel is -10 to + 10 volts and the second channel is
0 to +5 volts, enter
[-10,5]
Sample Time - Enter the base sample time or a multiple of the base sample
time.
Hardware Output Block Input Data Type Scaling
volts double 1
Input range (V) Range code Input range (V) Range code
-10 to +10 -10 0 - 10 10
-5 to + 5 -5 0 - 5 5