Specifications

PCL-818
7-21
BaseAddress - Enter the base address of the board. It is important that this
entry corresponds to the DIP-switch settings on the board. For example, if the
base address is 300 (hexadecimal), enter
0x300
PCL-818 Digital Input
Scaling of Input to Output
Driver Block Parameters
Channel Vector - Enter numbers between 1 and 16. This driver allows the
selection of individual digital input lines in any order. The number of elements
defines the number of digital lines used.
For example, to use the first eight digital inputs, enter
[1,2,3,4,5,6,7,8]
Number the lines beginning with 1 even if the board manufacture starts
numbering the lines with 0.
Sampletime - Enter a base sample time or a multiple of the base sample time.
BaseAddress - Enter the base address of the board. This entry must
corresponds to the DIP-switch settings on the board. For example, if the base
address is 300 (hexadecimal), enter
0x300
Hardware Input Block Output Data Type Scaling
TTL double TTL low = 0.0
TTL high = 1.0