Specifications
PA-1700
6-7
Hystheresis - From the list choose either off or on. The Hystheresis
parameter specifies if a counter should skip a tick if the direction changes (see
the PA1700 manual).
Resolution - The Resolution field specifies the resolution of the connected
incremental encoder for one revolution.
Sampletime - Model base sample time or a multiple of the base sample time.
BaseAddress - Enter the base address of the board. It is important that this
entry corresponds to the DIP-switch settings on the board. For example, if the
base address is 300 (hexadecimal), enter
0x300
The following jumpers must be set according to the parameters entered above:
•Jumper J16, 17 and 18 must be set to position 1-2
•Jumper J13, 14 and 15 must be set to position 1-2
•Jumper J1, 5 and 9 must be set according to the connected encoders
•Jumper J2, 6 and 10 must be set according to the connected encoders
•Jumper J3, 7 and 11 must be set according to the connected encoders
•Jumper J4, 8 and 12 must be set according to the connected encoders
For information on how to electrically connect the encoders to the board, see
the PA1700-manual.
If you want to use the 5V power supply from the board (PIN20), you have to
insert Fuse 1 on the board. Refer to the PA1700-manual.