Specifications

CAN FIFO Driver Blocks for the CAN-AC2-104 with Philips SJA1000 CAN-Controller
5-33
The dialog box of the block lets you define the following settings.
CAN port — Defines the filter criterion for the CAN port. Possible choices are:
Any, 1 or 2.
Message type command — Defines the filter criterion for the event types. This
entry can consist of a concatenation of space delimited keywords which are:
SDF Standard data frame
SRF Standard remote frame
EDF Extended data frame
ERF Extended remote frame
EF Error frame
NE No new event
CBS Change of bus state
Message type selection mode — Defines how the event type (message type)
entered in the control above is treated. If you select Include, the event type
criterion is the sum of the concatenated keywords. If you select Exclude, the
event type criterion is equal to all event types minus the sum of the
concatenated keywords.
Identifier(s) Defines the filter criterion for the CAN message identifiers. A
set of identifiers can be provided as a row vector.