Specifications
CAN FIFO driver blocks for the CAN-AC2-PCI with Philips SJA1000 CAN-Controller
5-21
FIFO Reset RCV Driver Block
The FIFO Reset RCV driver block is used to reset the receive FIFO. This will
delete all messages currently stored in the receive FIFO and reset the level
counter to 0. As an example, you can use this driver block to reset the receive
FIFO after having detected a fault condition.
The block has a single input port of type double. If a scalar value of 1 is passed,
the transmit FIFO gets reset. If a scalar value of 0 is passed, no action takes
place.
The dialog box of the block lets you define the following settings.
Board — Defines which physically present board is accessed to reset the
receive FIFO. For more information about the meaning of the board number
see the Setup driver block described above. If just one board is present in the
target system, board number 1 should be selected.
Sample time — Defines the sample time at which the FIFO Reset RCV driver
block is executed during a model (target application) run.