User manual
28
String parameters supported
In Dymola 2015 string parameters are supported in FMUs. For the FMU export to support
string parameters, the following flag must be set:
Advanced.AllowStringParameters=true
The flag is by default false.
(String variables are however presently not supported.)
Example
String parameter support can be illustrated by a simple example of changing tables for an
FMU; consider creating a simple model for linearization.
Create a model; drag an instance of
Modelica.Blocks.Tables.CombiTable2D into the
model. Connect the two inputs and the output and create the corresponding connectors. The
result is:
In the parameter dialog of combiTable2D, select
tableOnFile to true, and propagate
tableName and fileName. Give relevant default values for them. As an example, looking at
the resulting Modelica code when having specified a table name and file name as default
value, we find:
Saving the model, and then generating an FMU from it (do not forget to set the flag above),
we can import this FMU and look at the resulting parameter dialog of an instance of that
FMU: