User`s guide

Using Impulse- and Step-Response Plots to Validate Models
Transient Response Plot Settings (Continued)
Action
Command
Display impulse response for
linear m odel.
Select Options > Impulse response.
Note Not available for nonlinear
models.
Display the co ndence interval.
Note Only available for linear
models.
To display the dashed lines on either
side of the nominal model curve ,
select Options > Show condence
intervals. Select this option again to
hide the condence intervals.
To change the condence value, select
Options > Set % condence level,
andchooseavaluefromthelist.
To enter y our own condence level,
select Options > Set condence
level > Other. Enter the value as a
probability (between 0 and 1) or as
the number of standard deviations o f
a Gaussian distribution .