User`s guide

1 Data Processing
To extract a subset of time-domain data and save it as a new data set:
1 Import time-domain data into the System Identication Tool GUI, as
described i n “R epresenting Da ta in the GUI” o n page 1-13.
2 Drag the data set you want to subset to the Working Data area.
3 If your data contains multiple I/O channels, in the Channel menu, select
thechannelpairyouwanttoview.Theupperplotcorrespondstotheinput
signal, and the lower plot corresponds to the output signal.
Although you view only one I/O channel pair at a time, your data selection
is applied to all chann els in this data set.
4 Select the data of interest in either of th e following ways:
Graphically Draw a rectangle on either the input-signal or the
output-signal plot w ith the mouse to select the desired time interval.
Your selection app ea r s on both plots regard le ss of the plot on which you
draw the rectangle. The Time span and Samples elds are updated to
match the selected region.
By specifying the Tim e span Edit the beginning and the end times
in seconds. The Samples eldisupdatedtomatchtheselectedregion.
For example:
28.5 56.8
By specifying the Samp les range Edit the beginning and the end
indices of the sample range. The Time span eld is updated to match
the selected region. For example:
342 654
Note To clear your selection, click Revert.
5 In the Data name eld, enter the name of the data set containing the
selected data.
6 Click Insert. This action saves the sele ction as a new data set and adds
it to the Data Board.
1-88