User`s guide
Create a Procedural-Based Configuration
27-7
8
In the Action section of the Model Advisor dialog box, click Fix block fonts.
9
In the left pane of the Model Advisor, select My Procedure. In the right pane of the
Model Advisor, click Run All. The Check Simulink block font check passes. The
Model Advisor runs the Check Simulink window screen color check. This check fails
and the Model Advisor stops checking.
10
In the Action section of the Model Advisor dialog box, click Fix window screen
color.
11
In the left pane of the Model Advisor, select My sub_Procedure. In the right pane of
the Model Advisor, click Run All. The Check Simulink window screen color check
passes. The Model Advisor runs the Check model optimization settings check. This
check warns.
12
In the Action section of the Model Advisor dialog box, click Fix model
optimization settings.
13
In the left pane of the Model Advisor, select Check model optimization settings.
In the right pane of the Model Advisor, click Run This Task. The Check model
optimization settings check passes.