User`s guide
18 Coverage Collection During Simulation
18-12
models whose simulation mode is Normal. In this example, only the first Model
block that references sldemo_mdlref_counter_datamngt is available for
recording coverage.
d
Click OK to exit the Select Models for Coverage Analysis dialog box.
e
In the Coverage Settings dialog box, on the Reporting tab, select Last Run
so that you can compare coverage data from individual simulations, not
accumulated coverage for successive simulations.
3
Click OK to save your coverage settings and exit the Coverage Settings dialog box.
4
Simulate your model.
When the simulation is complete, the HTML coverage report opens. In this example,
the coverage data for the referenced model, sldemo_mdlref_counter_datamngt,
shows that the model achieved 69% coverage.
5
Click the hyperlink in the report for the referenced model.
The detailed coverage report for the referenced model opens, and the referenced
model appears with highlighting to show coverage results.