User`s guide
17 Setting Model Coverage Options
17-14
Restrict recording to interval
To record model coverage only inside a specified simulation time interval, check Restrict
recording to interval and define a Start time and Stop time. Model coverage is not
recorded for simulation times outside Start time and Stop time. If your simulation
starts at a time greater than or equal to Stop time, model coverage is not recorded.
For example, you might want to restrict model coverage recording if your model has
transient effects early in simulation, or if you need model coverage reported only for a
particular model operation.
Boundary Tolerance — Absolute
Specify the value of absolute tolerance for relational boundary coverage of floating point
inputs. For more information, see “Relational Boundary Coverage”.
Boundary Tolerance — Relative
Specify the value of relative tolerance for relational boundary coverage of floating point
inputs. For more information, see “Relational Boundary Coverage”.
Filter Tab
On the Filter tab, enter the file name that specifies the model objects to be excluded
from model coverage collection. You can use the same filter file for multiple models.