User`s guide
Model Objects That Do Not Receive Coverage
16-33
Model Objects That Do Not Receive Coverage
The Simulink Verification and Validation software does not record coverage for blocks
that are not listed in “Model Objects That Receive Coverage”.
Note: The software only records coverage when the Simulation mode parameter is set
to Normal.
The following table identifies specific model objects that do not receive coverage in
certain conditions.
Model object Does not receive coverage...
Logical Operator block When the Operator parameter specifies
XOR or NXOR and there are two or more
inputs.
Model blocks When the Simulation mode parameter
specifies Accelerator.
Coverage for Model blocks is the sum of
the coverage data for the contents of the
referenced model.
Subsystem block When the Read/Write Permissions
parameter is set to NoReadOrWrite.
Stateflow chart
MATLAB Function block
When debugging/animation is not enabled
for the model or object.