User`s guide

IBM Rational DOORS
7-3
Follow the instructions in “Configure RMI for IBM Rational DOORS or Microsoft ActiveX
Navigation” on page 2-12.
Manually Install Additional Files for DOORS Software
The setup script automatically copies the required DOORS files to the installation
folders. However, the script might fail because of file permissions in your DOORS
installation. If the script fails, change the file permissions on the DOORS installation
folders and rerun the script.
You can also manually install the required files into the specified folders, as described in
the following steps:
1
If the DOORS software is running, close the application.
2
Copy the following files from matlabroot\toolbox\slvnv\reqmgt to the
<doors_install_dir>\lib\dxl\addins folder.
addins.idx
addins.hlp
If you have not modified the files, replace any existing versions of the files;
otherwise, merge the contents of both files into a single file.
3
Copy the following files from matlabroot\toolbox\slvnv\reqmgt to the
<doors_install_dir>\lib\dxl\addins\dmi folder.
dmi.hlp
dmi.idx
dmi.inc
runsim.dxl
selblk.dxl
Replace any existing versions of these files.
4
Open the <doors_install_dir>\lib\dxl\startup.dxl file. In the user-defined
files section, add the following include statement:
#include <addins/dmi/dmi.inc>
If you upgrade from Version 7.1 to a later version of the DOORS software, perform
these additional steps:
a
In your DOORS installation folder, navigate to the ...\lib\dxl
\startupFiles subfolder.