User`s guide

4 Reviewing Requirements
4-6
1
Open the example model:
slvnvdemo_fuelsys_officereq
2
In the Simulink Editor, select Analysis > Requirements Traceability >
Highlight Model.
3
Open the fuel rate controller subsystem.
The Airflow calculation subsystem has a requirements link.
4
Open the Airflow calculation subsystem.
5
In the Simulink Editor, select View > Library Browser.
6
On the Libraries pane, select Simulink Verification and Validation.
This library contains only one block—the System Requirements block.
7
Drag a System Requirements block into the Airflow calculation subsystem.
The RMI software collects and displays any requirements links for that subsystem in
the System Requirements block.
8
In the System Requirements block, double-click 1. “Mass airflow subsystem”.
The Microsoft Word document, slvnvdemo_FuelSys_DesignDescription.docx,
opens, with the section 2.1 Mass airflow estimation selected.