User`s guide

Window Function
5-544
Dialog Box
Operation
The block’s operation: Apply window to input, Generate window, or
Generate and apply window. The input/output port configuration is
updated to match the parameter setting.
Window type
The type of window to apply. Tunable.
Window length
The length of the window to apply. This parameter is available only when
Generate window is selected in the Operation menu. Otherwise, the
window vector length is computed to match the input frame size, M.
Sampling
The window sampling for generalized-cosine windows,
Symmetric or
Periodic. Tunable.
Stopband attenuation in dB
(Not shown in dialog above. Visible for the
Chebyshev window.) The level
(dB) of stopband attenuation, R
s
. Tunable.
Beta
(Not shown in dialog above. Visible for the
Kaiser window.) The Kaiser
window β parameter. Increasing β widens the mainlobe and decreases the
amplitude of the window sidelobes in the window’s frequency magnitude
response. Tunable.