User`s guide

LMS Adaptive Filter
5-270
Dialog Box
FIR filter length
The length of the FIR filter.
Step-size
The step size, usually in the range (0, 2). Tunable.
Initial value of filter taps
The initial FIR filter coefficients.
Leakage factor
The leakage factor, in the range [0, 1]. Tunable.
Use normalization
Select or deselect normalization.
Adapt input
Enables the
Adapt port.
References Haykin, S. Adaptive Filter Theory. 3rd ed. Englewood Cliffs, NJ: Prentice Hall,
1996.
Supported
Data Types
Double-precision floating point