User`s guide
Dyadic Analysis Filter Bank
5-156
Latency
Zero Latency. The Dyadic Analysis Filter Bank block has no tasking latency for
frame-based operation, which is always single-rate. The block therefore
analyzes the first input sample (received at t=0) to produce the first output
sample at each port.
Nonzero Latency. The Dyadic Analysis Filter Bank block has tasking latency
only for sample-based operation, which is always multirate. As shown in the
table below, the amount of latency, D, depends on the structure (symmetric or
asymmetric) of the n-level tree used by the block.
In the above cases, the block repeats a zero initial condition in each channel for
the first D output samples. For example, in single-tasking mode, the
asymmetric tree structure generates 2
n-1
zero-valued output samples at each
port in each channel before propagating the first analyzed input sample
(computed from the input received at t=0).
See “Excess Algorithmic Delay (Tasking Latency)” in Chapter 3 and “The
Simulation Parameters Dialog Box” in the Simulink documentation for more
information about block rates and Simulink’s tasking modes.
Multirate... Symmetric Tree Asymmetric Tree
Single-tasking
One sample 2
n-1
samples
Multitasking
One sample 2
n-1
samples
F
s
/
2F
s
/
4F
s
/
8F
s
/
16
F
s
/32
F
s
/64
F
s
/128
F
s
/256
0
F
s