Specifications

3 Designing Controllers Using the Design Tool GUI
3-20
To delete a single data marker, right-click it and select the Delete option.
Right-Click Options
Right-click a data marker to use one of the following options:
Alignment – Relocate the marker's label.
Font Size – Change the label's font size.
Movable – On/off option that makes the marker movable or fixed.
Delete – Deletes the selected marker.
Interpolation – Interpolate linearly between the curve's data points, or locate at the
nearest data point.
Track Mode – Changes the way the marker responds when you drag it.
Displaying Multiple Scenarios
By default the response plots include all the scenarios you've simulated. The example
below shows a response plot for a plant with two outputs. The data markers indicate the
two scenarios being plotted: “Accurate Model” and “Perturbed Model”. Both scenarios use
the same setpoints (not marked—the lighter solid lines).
Viewing Selected Scenarios
If your plots are too cluttered, you can hide selected scenarios. To do so:
Right-click in the plot's white space.
Select Responses from the resulting context menu.
Toggle a response on or off using the submenu.
Note This selection affects all variables being plotted.