Plant Inputs for the T Setpoint Scenario
Plant Outputs for T Setpoint Scenario with Added Data Markers shows that the
reactor temperature setpoint increases suddenly by 2 degrees at t = 5, as you specified
when defining the scenario in “Defining Simulation Conditions” on page 3-11.
Unfortunately, the temperature does not track the setpoint very well, and there is a
persistent error of about 1.6 degrees at the end of the simulation.
Also, the controller requests a sudden jump in the coolant temperature (see the upper
graph in Plant Inputs for the T Setpoint Scenario), which might be difficult to deliver
in practice. (The lower graph in Plant Inputs for the T Setpoint Scenario shows that the
feed concentration, C
Ai
, remains constant, as specified in the scenario.)
See “Change Controller Settings” on page 3-23 for ways to overcome these
deficiencies.
Note Plant Outputs for T Setpoint Scenario with Added Data Markers has data markers.
To add these, left-click the curve to create the data marker. Drag a marker to relocate