Specifications

2 Building Models
2-18
Distillate Purity: exp(-1*s) * ----------
16.7 s + 1
6.6
Bottoms Purity: exp(-7*s) * ----------
10.9 s + 1
From input "Steam Rate" to output...
-18.9
Distillate Purity: exp(-3*s) * --------
21 s + 1
-19.4
Bottoms Purity: exp(-3*s) * ----------
14.4 s + 1
From input "Feed Rate" to output...
3.8
Distillate Purity: exp(-8.1*s) * ----------
14.9 s + 1
4.9
Bottoms Purity: exp(-3.4*s) * ----------
13.2 s + 1
Input groups:
Name Channels
Measured 3
Manipulated 1,2
Output groups:
Name Channels
Measured 1,2
Continuous-time transfer function.
The code defines the individual transfer functions, and then forms a matrix in which
each row contains the transfer functions for a particular output, and each column
corresponds to a particular input. The code also sets the signal names and designates the
third input as a measured disturbance.