User`s guide

Setting Acquisition Parameters in Image Acquisition Tool
3-27
You can clear the drawn region before you commit it by single-clicking anywhere in
the Preview Window outside of the selected area. You will still be in ROI selection
mode. If you want to clear the selected region and exit ROI selection mode, press
the Delete key, press the Escape key, or use the right-click menu Exit Region of
Interest Mode inside the region.
Note: If you start another acquisition with the same device, the ROI that you set will
remain the default that is used in subsequent acquisitions. To reset to the original image
size, click the Reset Region of Interest to Maximum button in the Preview Window
or the Reset button on the Region of Interest tab.
Restoring Default Parameters
Once you have changed parameters of a device, you can restore the device's default
parameters by selecting the device format in the Hardware Browser and right-clicking
Clear Selected Hardware Configuration. That clears any changes you have made
and resets the default parameters of that device format.
If you want to save a configuration before clearing it, first select Export Selected
Hardware Configuration from the right-click menu.