The camera starts integration of incoming light from the first external trigger input
falling edge and exposes incoming light at shutter time. Repeat this sequence until the
Nth external trigger input falling edge, then finish integration. Parameter N is required
and must be 1 or greater (N >= 1).
Trigger Mode 5
This mode is the “multiple shutter pulse width mode.” It is a combination of modes 1 and
2. The exposure time is governed by the duration of the trigger signal and a number of
trigger signals can be integrated into a single readout. If the trigger parameter is 1, this
mode is degenerate with mode 1.
A parameter is required. The parameter describes the number of triggers.
The camera starts integration of incoming light from first the external trigger input
falling edge and exposes incoming light until the trigger is inactive. Repeat this sequence
until the Nth external trigger input falling edge, then finish integration. Parameter N is
required and must be 1 or greater (N >= 1).