User`s guide
8 Test Suite for Adaptor Writers
8-6
Specifying Format of Image Data Test Procedure
As part of the Image Acquisition Toolbox Adaptor Kit, we now offer a test procedure and
automated tests for third-party adaptor developers and camera vendors to test adaptors
and hardware against the toolbox. This test procedure is part of that suite. For more
information, see “Testing Adaptors or Hardware” on page 8-2.
After specifying the format of the image data per instructions in “Specifying the
Format of the Image Data” in this Adaptor Kit documentation, follow these steps to test
specifying the format of the image data.
Test Procedures Expected Results
Run the following commands:
vidObj = videoinput
('AdaptorName');
vidObj.VideoResolution
vidObj.VideoFormat
delete(vidObj);
clear vidObj;
The output should be the width and height
(e.g. 640 480) of the frame to be acquired.
The output should indicate the Video Format
(e.g. MJPG_640x480).
To clean up after this step, delete and clear
the object:
delete(vidObj);
clear vidObj;