User`s guide

5 Acqu iring Image Data
Controlling Logging Parameters
In this section.. .
“Data Logging” on p age 5-20
“Specifying Logging Mode” on page 5-20
“Specifying the Number of Frames to Log” on page 5-21
“Determining How Much Data Has Been Logged” o n page 5-23
“Determining How Many Frames Are Available” on page 5-25
“Delaying Data Logging After a Trigger” on page 5-28
“Specifying Multiple Triggers” on page 5-29
Data Logging
The following subsections describe how to control various aspects of data
logging.
Specifying the logging mode
Specifying the number of frames to log
Determining how many frames have been logged since the object was
started
Determining how many frames are currently available in the mem ory buffer
Delaying data logging after a trigger executes
Specifying multip le trigger executions
Specifying Logging Mo de
Using the video input object LoggingMode property, you can control w here the
toolbox logs acquired frames of data.
The default value for the
LoggingMode property is 'memory'.Inthismode,
the toolbox logs data to a buffer in memory. If you want to bring image data
into the M ATLAB workspace, you must log frames to memory. The functions
provided by the toolbox to move data into the workspace all work with the
5-20