User`s guide
3 Project Generator
3 Under Code Generation, select Inline run-time library functions.
Cleartheotheroptions.
4 Under Link Automation,verifythatExport IDE link h an dle to base
workspace is selected and provide a name for the hand le in IDE handle
name (optional).
5 Set Byte ordering to Little endian.
6 Change the category back to Embedded IDE Link CC.
7 Set the following Runtime options:
• Build action:
Create_project.
• Interrupt overrun notification method:
None.
8 Change the category on the Select tree to Hardware Implementation.
Simulink
You have configured the Real-Time Workshop software options that let you
generate a project for you processor. You may have noticed that you did not
configure a few categories on the Select tree, such as
Comments, Symbols,
and
Optimization.
For your new model, the default values for the options in these categories
are correct. For other m odels y ou develop, you may want to se t the options
in these categories to provide information during the build and to run TLC
debugging when you generate code. Refer to your Simulink and Real-Time
Workshop documentation for more information about setting the configuratio n
parameters.
Building Your Project
After you set the configuration parameters and configure Real-Tim e Worksho p
software to create the file s you need, you dire ct the build process to create
your project:
1 Press OK to close the Configuration Parameters dialog box.
2 Click Ctrl+B to generate your project into CCS IDE.
3-46