Specifications
Running the Modified Program
Connecting to I/O Devices
7-17
7.8 Running the Modified Program
1) Choose Project
→
Rebuild All or click the (Rebuild All) toolbar button.
2) Choose File
→
Load Program. Select the program you just rebuilt,
hostio.out, and click Open.
3) Choose Tools
→
DSP/BIOS
→
Host Channel Control. The Host Channel
Control lists the HST objects and allows you to bind them to files on the
host PC and to start and stop the channels.
4) Choose Debug
→
Run or click the (Run) toolbar button.
5) Right-click on the input_HST channel and choose Bind from the pop-up
menu.
6) Select the input.dat file in your working folder and click Bind.
7) Right-click on the output_HST channel and choose Bind from the pop-up
menu.
8) Type
output.dat
in the File Name box and click Bind.
9) Right-click on the input_HST channel and choose Start from the pop-up
menu.
10) Right-click on the output_HST channel and choose Start from the pop-up
menu. Notice that the Transferred column shows that data is being
transferred.
11) When the data has been transferred, click (Halt) or press Shift F5 to
stop the program.
7.9 Learning More
To learn more about the RTDX, HST, PIP, and SWI modules, see the online
help or the
TMS320C6000 DSP/BIOS User’s Guide
(which is provided as an
Adobe Acrobat file).