Specifications

Table Of Contents
10 Design Case Studies
10-30
The command produces the plot shown below.
This design is robust and can tolerate a 11 dB gain increase or a 40 degree
phase lag in the open-loop system without going unstable. By continuing this
design process, you may be able to find a compensator that stabilizes the
open-loop system and allows you to reduce the seek time.