10 Long Term Storage
For long term inactivity periods it is necessary to store the modules in a dry place protected from
atmospheric agents, making sure to protect them to avoid damage.
Before storage it is recommended to clean the products.
Both the backup battery of the MOD_HWT_INT module, and the CR2032 button battery of the
MOD_MPYV2_SPAY_C1 module, must be disconnected from the respective modules.
Table 9 shows the temperature limits allowed in case of storage for the modules and the
respective batteries
Device
Storage Temperature Range
MOD_HWT_INT Module
-20°C / +70°C
MOD_MPYV2_SPAY_C1 Module
-20°C / +70°C
Battery HOWELL Model
HW484594
-20°C / +45°C
Button Battery Model Panasonic
CR2032 3V 220mAh
-30°C / +60°C
Table 9 Storage Temperature Range Long Term.
It is also recommended for the backup battery present inside the MOD_HWT_INT module, to
check every 3 months that the voltage present at its ends is within the range of values 3,6V-
3,9V.
If the aforementioned check notifies a voltage value outside those indicated, we strongly
recommend that you restore the temperature conditions declared in the previous paragraph.