Telemetry KIT MPYV2 User Manual and Maintenance Document code: MPYV2-KMT.HL.MUM.001_ENG - rev. 1.1 Page 1 / 43 Telemetry KIT MPYV2 User Manual and Maintenance 1.1 Rev. 24/06/2020 A. De Gregorio Date Edited: F. De Palma F. Liuzzi Controlled: Approved: The copyright of this document is vested in Matipay S.r.l. - This document can not be reproduced in whole or in part, or stored in a retrieval system, or transmitted in any form, or by any means without the prior permission of Matipay S.r.l.
Telemetry KIT MPYV2 User Manual and Maintenance Document code: MPYV2-KMT.HL.MUM.001_ENG - rev. 1.1 Page 2 / 43 History of Revisions Rev. Date Description Edited: 1.1 24/06/2020 Para 5.1 added additional statement, Para 5.2 entirely added A. De Gregorio 1.0 21/05/2020 First Issue A. De Gregorio The copyright of this document is vested in Matipay S.r.l.
Telemetry KIT MPYV2 User Manual and Maintenance Document code: MPYV2-KMT.HL.MUM.001_ENG - rev. 1.1 Page 3 / 43 Annexes Document Code Rev. Date WI9250PM1_H04 0.1 26/02/2020 Document Title MOD_MPYV2_SPAY_C1 (MOUNTING TEMPLATE) (print in A3 format) The copyright of this document is vested in Matipay S.r.l. - This document can not be reproduced in whole or in part, or stored in a retrieval system, or transmitted in any form, or by any means without the prior permission of Matipay S.r.l.
Telemetry KIT MPYV2 User Manual and Maintenance Document code: MPYV2-KMT.HL.MUM.001_ENG - rev. 1.1 Page 4 / 43 Index 1 Introduction .................................................................................... 8 1.1 Applicable Documents ........................................................................................ 8 1.2 Acronyms ........................................................................................................... 8 1.3 Scope .....................................
Telemetry KIT MPYV2 User Manual and Maintenance Document code: MPYV2-KMT.HL.MUM.001_ENG - rev. 1.1 Page 5 / 43 12 Proper product disposal................................................................ 38 13 Radio Modules Data ....................................................................... 39 13.1 Radio Modules Data.......................................................................................... 39 13.1.1 GSM/GPRS Modem ....................................................................
Telemetry KIT MPYV2 User Manual and Maintenance Document code: MPYV2-KMT.HL.MUM.001_ENG - rev. 1.1 Page 6 / 43 Index of Figures Figure 1 – Application Context ...................................................................................... 10 Figure 2 – MOD_HWT_INT, views, slots and connectors. .................................................. 11 Figure 3 - MOD_MPYV2_SPAY_C1, front and rear view. .................................................... 13 Figure 4 - CABLE_CUSTOM_MAIN/SLAVE_BOARD ......
Telemetry KIT MPYV2 User Manual and Maintenance Document code: MPYV2-KMT.HL.MUM.001_ENG - rev. 1.1 Page 7 / 43 Index of Tables Table 1 – Acronyms ....................................................................................................... 8 Table 2 – MOD_HWT_INT, connectors description, slots e switches. ................................... 12 Table 3 – MOD_HWT_INT, ports/interfaces correspondence and connectors ........................ 12 Table 4 –MOD_MPYV2_SPAY_C, connectors. .................
Telemetry KIT MPYV2 User Manual and Maintenance Document code: MPYV2-KMT.HL.MUM.001_ENG - rev. 1.1 1 Page 8 / 43 Introduction 1.1 Applicable Documents [App.1] ARG.CE.RCH «Analisi 11/07/2016 [App.2] MPYV2.HL.HA.010 «Analisi dei Rischi (Safety)- Modulo di Pagamento», rev. 1.0, 10/02/2020 [App.3] MPYV2.HL.AP.005 «Albero di Prodotto», rev. 1.0, 29/01/2020 1.2 di Rischio Modulo Telemetrico MOD_HWT», rev. 0.
Telemetry KIT MPYV2 User Manual and Maintenance Document code: MPYV2-KMT.HL.MUM.001_ENG - rev. 1.1 2 Page 9 / 43 Introduction This manual contains the description of the operations and the instructions necessary to correctly carry out the main operations of use, ordinary and periodic maintenance of the modules defined in §1.4 (henceforth simply referred to as modules). For a practical consultation, this manual is divided into easily identifiable chapters.
Telemetry KIT MPYV2 User Manual and Maintenance Document code: MPYV2-KMT.HL.MUM.001_ENG - rev. 1.1 3 Page 10 / 43 General Description The modules are designed for use in Vending Machine (called hereafter as VM). In Figure 1 is shown, for an illustrative purpose, the application context diagram of the MOD_HWT_INT and MOD_MPYV2_SPAY_C1 modules of the KIT, which allows communication between smartphones and VMs for the purchase of products, using wireless technologies such as NFC and Bluetooth LE.
Telemetry KIT MPYV2 User Manual and Maintenance Document code: MPYV2-KMT.HL.MUM.001_ENG - rev. 1.1 4 Page 11 / 43 MOD_HWT_INT Description The MATIPAY WI9152PMX MOD_HWT_INT module, hereinafter also referred to as the Telemetry Module, consists of an electronic card placed inside a plastic container with external dimensions 140x100x22mm and overall weight less than 200g. Inside the plastic container there is also a rechargeable LI-ION battery that provides power to the board in case of power failure.
Telemetry KIT MPYV2 User Manual and Maintenance Document code: MPYV2-KMT.HL.MUM.001_ENG - rev. 1.
Telemetry KIT MPYV2 User Manual and Maintenance Document code: MPYV2-KMT.HL.MUM.001_ENG - rev. 1.1 5 Page 13 / 43 MOD_MPYV2_SPAY_C1 Description The MATIPAY WI9250PM1 MOD_MPYV2_SPAY_C1 module, hereinafter also referred to as the Payment Module, consists of an electronic card placed inside a plastic container with external dimensions 105x84x19mm and overall weight less than 70g.
Telemetry KIT MPYV2 User Manual and Maintenance Document code: MPYV2-KMT.HL.MUM.001_ENG - rev. 1.1 Page 14 / 43 Item Connector Description 1 J4 J11 (Future Use) BT1 (Future Use) Power Supply Input Connector and Communication to MOD_HWT_INT 2 3 Power Supply Input Connector from VM (Future Use) Internal Connector for CR2032 button battery Table 4 –MOD_MPYV2_SPAY_C, connectors. Item 1 2 3 4 5 6 Port/Interface Q.
Telemetry KIT MPYV2 User Manual and Maintenance Document code: MPYV2-KMT.HL.MUM.001_ENG - rev. 1.1 Page 15 / 43 This equipment has been tested and found to comply with the limits for a Class B digital device, pursuant to part 15 of the FCC Rules. These limits are designed to provide reasonable protection against harmful interference in a residential installation.
Telemetry KIT MPYV2 User Manual and Maintenance Document code: MPYV2-KMT.HL.MUM.001_ENG - rev. 1.1 6 Page 16 / 43 Wiring and accessories This chapter lists and describes both the wirings supplied with the MOD_HWT_INT and MOD_MPYV2_SPAY_C1 modules and any optional wiring. 6.1 Wiring supplied The wirings described in Table 6 are supplied together with modules. The length of all supplied wirings is less than 3 meters.
Telemetry KIT MPYV2 User Manual and Maintenance Document code: MPYV2-KMT.HL.MUM.001_ENG - rev. 1.1 Page 17 / 43 Cable for Telemetry Module to Payment Module 2.0 connection and pinout: Main Module External Module Figure 4 - CABLE_CUSTOM_MAIN/SLAVE_BOARD The copyright of this document is vested in Matipay S.r.l. - This document can not be reproduced in whole or in part, or stored in a retrieval system, or transmitted in any form, or by any means without the prior permission of Matipay S.r.l.
Telemetry KIT MPYV2 User Manual and Maintenance Document code: MPYV2-KMT.HL.MUM.001_ENG - rev. 1.1 Page 18 / 43 Cable for Telemetry Module to Vending Machine connection and pinout: Figure 5 - CABLE_CUSTOM_MDB/EVA-DTS_POWERSUPPLY The copyright of this document is vested in Matipay S.r.l. - This document can not be reproduced in whole or in part, or stored in a retrieval system, or transmitted in any form, or by any means without the prior permission of Matipay S.r.l.
Telemetry KIT MPYV2 User Manual and Maintenance Document code: MPYV2-KMT.HL.MUM.001_ENG - rev. 1.1 6.2 Page 19 / 43 Accessories and optional wirings ACCESSORIES/WIRINGS NAME PART NUMBER GSM/GPRS ANTENNA VARBM02812XXXAA CABLE_CUSTOM_ TX RX DB9 FAS INVERSION CAVI9168PMXAG MicroSD HC Class 10 (preformatted with FAT32 file system) Table 7 – Accessories and optional wirings The GSM / GPRS antenna is supplied, on request, as an optional accessory. It is already equipped with cables and connectors.
Telemetry KIT MPYV2 User Manual and Maintenance Document code: MPYV2-KMT.HL.MUM.001_ENG - rev. 1.1 7 7.1 Page 20 / 43 Preliminary operations and maintenance Modules installation The modules are intended exclusively for installation on Vending Machines equipped with an MDB and EVA-DTS communication port. The MOD_HWT_INT Telemetry Module is installed inside the VM while the Payment Module 2.0 MOD_MPYV2_SPAY_C1 is installed on the front of the VM. Below are reported the mounting methods for each unit.
Telemetry KIT MPYV2 User Manual and Maintenance Document code: MPYV2-KMT.HL.MUM.001_ENG - rev. 1.1 Page 21 / 43 Apply a slight pressure on the tabs 1 and 3 indicated in Figure 8 and at the same time act to release the upper part of the module casing. Then repeat the procedure on the tabs marked with 2 and 4 in Figure 8. At this point the upper part of the casing will be released from the lower one as illustrated in Figure 9.
Telemetry KIT MPYV2 User Manual and Maintenance Document code: MPYV2-KMT.HL.MUM.001_ENG - rev. 1.1 Page 22 / 43 Once the upper part of the module casing has been removed, a situation like the one shown in Figure 10 is presented. At this point, connect the backup battery connector to connector J3 indicated by the red arrow in Figure 10. For the correct use and disposal of the backup battery, refer to the procedure indicated in §8.
Telemetry KIT MPYV2 User Manual and Maintenance Document code: MPYV2-KMT.HL.MUM.001_ENG - rev. 1.1 Page 23 / 43 The method of MOD_HWT_INT module fixing is at the discretion of the installer. For this purpose, the use of cable ties is recommended. It is strongly advised against the use of double-sided tape or products that may lose adhesive capacity over time or due to temperature changes. 7.1.2 MOD_MPYV2_SPAY_C1 Installation The Payment Module 2.
Telemetry KIT MPYV2 User Manual and Maintenance Document code: MPYV2-KMT.HL.MUM.001_ENG - rev. 1.1 Page 24 / 43 Figure 1 – MOD_MPYV2_SPAY_C1, battery holder. 7.1.3 Modules connection Carry out the following steps in sequence. Connect the modules to each other by means of the CABLE_CUSTOM_MAIN/SLAVE_BOARD (see Figure 4), as shown in Figure 12. This cable has a length less than 3 meters. Figure 12 – Connection with CABLE_CUSTOM_MAIN/SLAVE_BOARD The copyright of this document is vested in Matipay S.r.l.
Telemetry KIT MPYV2 User Manual and Maintenance Document code: MPYV2-KMT.HL.MUM.001_ENG - rev. 1.1 Page 25 / 43 Connect the Telemetry Module MOD_HWT_INT to the VM internal devices by means of CABLE_CUSTOM_MDB/EVA-DTS_POWERSUPPLY (see Figure 5), as shown in Figure 13. This cable has a length less than 3 meters.
Telemetry KIT MPYV2 User Manual and Maintenance Document code: MPYV2-KMT.HL.MUM.001_ENG - rev. 1.1 Page 26 / 43 Screw the connector of the GPRS antenna to connector J5 on the MOD_HWT_INT module, as shown in Figure 14. If possible, it is recommended to position the GSM / GPRS antenna outside the VM. Figure 14 – MOD_HWT_INT, GPRS antenna connection 7.1.
Telemetry KIT MPYV2 User Manual and Maintenance Document code: MPYV2-KMT.HL.MUM.001_ENG - rev. 1.1 8 Page 27 / 43 Battery replacement and disposal The backup battery of the Telemetry Module must be replaced with a HOWELL type model HW484594 3.7V, or equivalent, under penalty of warranty void and the risk of any damage, even serious, to things or people The CR2032 button battery of the Payment Module 2.
Telemetry KIT MPYV2 User Manual and Maintenance Document code: MPYV2-KMT.HL.MUM.001_ENG - rev. 1.1 8.1 Page 28 / 43 Battery replacement and disposal of MOD_HWT_INT To replace the backup battery, follow the steps described below. Disconnect all the connectors from the MOD_HWT_INT module, until you are in the condition of Figure 15. Figure 15 –MOD_HWT_INT Module Extract the MOD_HWT_INT module from the VM.
Telemetry KIT MPYV2 User Manual and Maintenance Document code: MPYV2-KMT.HL.MUM.001_ENG - rev. 1.1 Page 29 / 43 Figure 16 – MOD_HWT_INT, details of opening tabs The copyright of this document is vested in Matipay S.r.l. - This document can not be reproduced in whole or in part, or stored in a retrieval system, or transmitted in any form, or by any means without the prior permission of Matipay S.r.l.
Telemetry KIT MPYV2 User Manual and Maintenance Document code: MPYV2-KMT.HL.MUM.001_ENG - rev. 1.1 Page 30 / 43 Figure 17 – MOD_HWT INT, enclosure disassembly The copyright of this document is vested in Matipay S.r.l. - This document can not be reproduced in whole or in part, or stored in a retrieval system, or transmitted in any form, or by any means without the prior permission of Matipay S.r.l.
Telemetry KIT MPYV2 User Manual and Maintenance Document code: MPYV2-KMT.HL.MUM.001_ENG - rev. 1.1 Page 31 / 43 Once the upper part of the module casing has been removed, a situation like the one shown in Figure 18 is presented. At this point, release the battery connector from connector J3 indicated by the red arrow in Figure 18. Figure 18 – MOD_HWT_INT, backup battery connector detail The copyright of this document is vested in Matipay S.r.l.
Telemetry KIT MPYV2 User Manual and Maintenance Document code: MPYV2-KMT.HL.MUM.001_ENG - rev. 1.1 Page 32 / 43 Separate the internal electronic card (having P/N BI9150PMX, see [App.3]) from the back of the casing; a situation like the one shown in Figure 19 is presented, with the backup battery to be replaced in its seat. Remove it and replace it with the new backup battery.
Telemetry KIT MPYV2 User Manual and Maintenance Document code: MPYV2-KMT.HL.MUM.001_ENG - rev. 1.1 8.2 Page 33 / 43 Battery replacement and disposal of MOD_MPYV2_SPAY_C The indications provided in this paragraph are to be considered when the use of this battery is foreseen by the manufacturer. The CR2032 battery is intended for "FUTURE USE". To insert or replace the CR2032 button battery, follow the steps described below.
Telemetry KIT MPYV2 User Manual and Maintenance Document code: MPYV2-KMT.HL.MUM.001_ENG - rev. 1.1 Page 34 / 43 BOTTOM NEGATIVE POLE (-) TOP POSITIVE POLE (+) Figure 21 – MOD_MPYV2_SPAY_C1, backup battery holder detail Place the module on the VM again and reconnect all the connectors. After making sure that all the cables have been connected correctly, power the VM again The correct disposal of the exhausted battery helps to avoid any negative consequences on the environment and health.
Telemetry KIT MPYV2 User Manual and Maintenance Document code: MPYV2-KMT.HL.MUM.001_ENG - rev. 1.1 9 Page 35 / 43 FAQ – Troubleshooting Before contacting the technical assistance service, carry out the simple checks listed in the following Troubleshooting Table.
Telemetry KIT MPYV2 User Manual and Maintenance Document code: MPYV2-KMT.HL.MUM.001_ENG - rev. 1.1 Page 36 / 43 10 Long Term Storage For long term inactivity periods it is necessary to store the modules in a dry place protected from atmospheric agents, making sure to protect them to avoid damage. Before storage it is recommended to clean the products.
Telemetry KIT MPYV2 User Manual and Maintenance Document code: MPYV2-KMT.HL.MUM.001_ENG - rev. 1.1 Page 37 / 43 11 Return to service After a long period of inactivity, before using the modules, it is necessary to check that they do not show any visible damage. In case of anomalies, check the interconnection cables between the modules and the VM and between the two modules. The copyright of this document is vested in Matipay S.r.l.
Telemetry KIT MPYV2 User Manual and Maintenance Document code: MPYV2-KMT.HL.MUM.001_ENG - rev. 1.1 Page 38 / 43 12 Proper product disposal (Disposal of electrical and electronic equipment at the end of useful life) (Applicable in European Union countries and other countries with separate waste collection system).
Telemetry KIT MPYV2 User Manual and Maintenance Document code: MPYV2-KMT.HL.MUM.001_ENG - rev. 1.1 Page 39 / 43 13 Radio Modules Data 13.1 Radio Modules Data 13.1.1 GSM/GPRS Modem The MOD_HWT_INT module is equipped with GSM/GPRS Radio interface. In the product it performs the function of GPRS data transmission / reception. It does not fulfill GSM voice functionality in any way.
Telemetry KIT MPYV2 User Manual and Maintenance Document code: MPYV2-KMT.HL.MUM.001_ENG - rev. 1.1 Page 40 / 43 13.1.2 Bluetooth LE The MOD_MPYV2_SPAY_C1 module is equipped with Bluetooth Low Energy (BLE) Radio interface. The Bluetooth LE module radio data are as follows: Parameter Mode and Conditions Min. Typ. Max.
Telemetry KIT MPYV2 User Manual and Maintenance Document code: MPYV2-KMT.HL.MUM.001_ENG - rev. 1.1 Page 41 / 43 13.1.3 NFC The MOD_MPYV2_SPAY_C1 module is equipped with Near Field Communication (NFC) interface. The NFC module radio data are as follows: Symbol Parameter Condition fo External RF signal frequency DR Data Rate Po Maximum Power Mod Modulation Type Interface Antenna Loop on PCB Min. Typ. Max. Unit - 13.
Telemetry KIT MPYV2 User Manual and Maintenance Document code: MPYV2-KMT.HL.MUM.001_ENG - rev. 1.1 Page 42 / 43 14 Dispositions Carefully check the device before each operation. Matipay S.r.l. cannot provide for any reasonably unforeseeable misuse which could lead to a potential danger. The modules are made up of plastic casings specifically designed for installation on a VM. Improper use could cause damage or malfunction of the modules. The modules do not have openings for internal ventilation.
Telemetry KIT MPYV2 User Manual and Maintenance Document code: MPYV2-KMT.HL.MUM.001_ENG - rev. 1.1 Page 43 / 43 15 Warranty The warranty period of the MOD_HWT_INT module, the MOD_MPYV2_SPAY_C1 module, and the accessories supplied is 12 months. The warranty period of the button battery is 6 months. The use of spare parts not approved by the manufacturer invalidates any warranty and relieves the manufacturer of any responsibility for malfunctions or accidents.