User guide
Temperature Controller iB6 / iB12
© Copyright Mastip Technology Limited. Information subject to alteration. V1.02 www.mastip.com
33
8.0 Resetting Default Values
8.1 Introduction
Using this function returns all configuration parameter values for the selected zone(s) to their
defaults (shown in Section 5). The setpoints for the selected zone(s) will be changed to 25 °C (77 °F).
Reloading defaults never affects the following settings that apply to the whole controller: display
units, input type. These settings that apply to the whole controller are not reset, even if all zones are
selected before loading defaults.
When all zones have been selected for resetting defaults, some settings that apply to the whole
controller WILL be reset to the defaults shown in shown in Section 5. These values that are returned
to the defaults include the Supervisor password (which will be reset to 100, disabling password
protection) and access control settings described in Section 7.
After loading defaults, you will need to cycle power to the controller before you can resume operation.
8.2 Procedure
To load defaults to selected zones:
1) Put the controller in the Idle state by pressing
for at least two seconds. (When the whole
controller is in the Idle state, only the green C or F LED will be lit.)
2) Select the zone for which you want to load defaults by pressing
until only that zones SP and
PV are displayed. Alternatively, select all zones by pressing
until all zones SP and PV are
displayed with asterisks
**
between the values for zones 3 and 4 (iB6), or between 3 and 4, and
9 and 10 (iB12).
3) Access the menu system by pressing
until a menu name is displayed, and then press
repeatedly until the name of the Superv Config menu is displayed.
4) Step through the parameters by pressing
repeatedly until Load Defaults is displayed.
5) Choose “Yes” by pressing
or
.
6) Exit the menu system by pressing and holding
until “Power Cycle the System” is displayed.
7) Cycle power to the controller. When powered up, the controller will use the default settings for
the zone(s) selected in step 2.