User guide

© Copyright Mastip Technology Limited. Information subject to alteration. V1.02 www.mastip.com
24
Temperature ControlleriB6 / iB12
5.5 Display Units
5.5.1 Introduction
On the front panel the lit green LED labeled C or F indicates the units of measure for the process
values and setpoints displayed.
You can use the Display Config menu to change the unit of measure used for displayed
temperatures.
5.0 Parameter Characteristics
Name Applies to Range/
Choices
Default Description & Interactions
Selected Zones
All Zones
Closed Loop Control
Open Loop Control
Startup Mode
Auto (Normal
closed loop)
Standby
Manual (open loop)
Idle (remains
in Idle after
is pushed to set
controller to Run
state)
Last Active Mode
(same mode as
last time controller
was running)
Mode used for the zone when
the controller goes from Idle to
Run (because operator pushed
on the front of the case)