5.3 Boost Parameters
5.3.1 Introduction
A boost button s on the iB6 and iB12 front panel. When you press , the output of a zones will
be increased temporarily.
You can use the Boost Config menu to specify:
• whether the boost function will be closed loop (based on a setpoint) or open loop (based on a
specified output percent)
• boost setpoint and duration for closed loop boost
• boost output percentage and duration for open loop boost
5.3.2 Boost Parameters and Settings
5.0 Parameter Characteristics
Name Applies to Range/
Choices
Default Description & Interactions
Selected Zones
All Zones
Closed Loop Control
Open Loop Control
Boost Type
Open Loop
Closed Loop
Closed Loop
Type of control used after is
pressed; applies only to zones
running in Normal mode; zones
running in Manual mode always
use Closed Loop boost
Boost
Duration
Boost Off
15 seconds
30 seconds
45 seconds
60 seconds
75 seconds
90 seconds
105 seconds
120 seconds
Boost Off Length of boost
Boost
Setpoint
Low Setpoint
Limit to High
Setpoint
Limit (from
Input Config
menu)
25 °C
77 °F
Setpoint used in Closed Loop
boost
Boost
Percentage
0 to 100% 0 (off) Output percent used in Open
Loop boost