3.0 User Interface
Menu Parameters Factory Setting
Display
Config
Display Units °C
6
Alarm
Config
Inhibit Seconds 0 (off)
High Dev Setpoint [High Deviation] 17 °C (30 °F)
Low Dev Setpoint [Low Deviation] 17 °C (30 °F)
Alarm Silence Seconds 120 seconds—applies to all zones
Superv.
Config
[Supervisor]
Set Superv. Password 100 = OFF (password protection
disabled) - applies to all zones
Fail Safe Action Auto Average (use a calculated
output value based on output values
that have typically successfully
maintained the current setpoint
for your process in the past; if no
history of Normal mode operation,
then output is set to zero) - applies
to selected zone
Low Reading Not applicable
High Reading Not applicable
High [Temperature] Safety [Limit] OFF - applies to selected zone
Fail Safe FOP [Fixed Output
Percent]
0 % - applies to selected zone
Loop Break Time 300 seconds - applies to selected zone
Soft Start (CompuStep® gradual
warming)
Enable - applies to all zones that
are in Normal (closed loop) mode
Mode Key Enable Enable - applies to all zones
Boost Key Enable Enable - applies to all zones
SP [Setpoint] Change Enable Enable - applies to all zones
Config. Enable Enable - applies to all zones
Reset PID Parameters No - applies to selected zone
Load Defaults No - applies to selected zone (but all
zones must be in Idle; changes take
effect after power has been cycled)