Instruction Manual

Mass 24/50, 24/75, 24/100, 48/25, 48/50 User and Installation Manual
17
6.4 Event based commands
With MasterBus a device can be programmed to initiate an action at another connected device. This is done by means of
event-based commands.
Events
Field
Meaning
Factory setting
Adjustable range
Event x source
Event-based command.
Mass Charger event that should result in an action by
another device on the MasterBus network.
Disabled
See Event source list.
Event x target
Select a connected MasterBus device that should take
action due to a Mass Charger event.
Select…
Selectable targets are
system dependent.
Event x
command
Action to be taken by the target device.
Select…
See command list in
selected device manual
Event x data
Data is linked to the command.
On changes the status to On at the first signal.
Off changes the status to Off at the first signal.
Copy lets the status follow the input.
Copy Invert lets the status follow the opposite of the input
Toggle changes the status at the 1
st
signal and back at the
2
nd
signal. It is used in combination with a pulse switch.
Off
Off, On, Copy,
Copy Invert, Toggle.
Event x+1
The next event appears after enabling Event x.
Disabled
See Event x.
Mass Charger event source list (Mass Charger as event source)
Event source
Meaning
Charging
Mass Charger state is On
Bulk
Charge stage is Bulk
Absorption
Charge stage is Absorption
Float
Charge stage is Float
Failure
Charger failure MasterBus alarm
CSI
Charger Status Interface MasterBus alarm to generate an audible alarm at charger failure
Equalize
Mass Charger is in Equalize mode
TC Error
Battery temperature sensor error
Fan
MasterBus signal for an external fan to start (at 50% load/50°C)
LED Bulk
LED Bulk illuminates
LED 20-40
LED 2 illuminates (see Figure 7)
LED Abs
LED Abs illuminates
LED 60-80
LED 4 illuminates (see Figure 7)
LED Float
LED Float illuminates
LED Failure
LED Failure illuminates
Mass Charger event target list (Mass Charger as event target)
Event target
Meaning
Bulk
Command to start the Bulk stage of charge
Absorption
Command to start the Absorption stage of charge
Float
Command to start the Float stage of charge
On/ Standby
Command to switch on the Mass Charger
Output reduction
Command to reduce the output of the Mass Charger
e.g. when set to 90%, max. current will be 10% when event is received