Specifications
SPECIFICATIONS IVO COMPACT
Model IVO Compact 12/25-3 IVO Compact 24/10-2
Article no. 43012500 43021000
DC
Charge voltage absorption (25°C) 14.25VDC 28.50VDC
Charge voltage float (Wet; 25°C) 13.25VDC 26.50VDC
Charge voltage float (Gel; 25°C) 13.80VDC 27.60VDC
Total charge current 25A 10A
DC consumption with connected battery <10mA <5mA
Number of outlets 2 main outputs + 1 slave 3A 1 main output + 1 slave 3A
Charge characteristics IUoUo / 3 stage / automatic / DIN 41772
Max. absorption time, reduced output 6 hours (adjustable) 6 hours (adjustable)
Temperature compensation 30mV/°C 60mV/°C
Voltage compensation Auto sense Auto sense
Recommended DC fuse (Main) 30A-T 20A-T
Recommended DC fuse (Slave) 5A-T 5A-T
Wire size < 1.5m 6 mm²/AWG9 4mm²/AWG11
Wire size > 1.5m 10mm²/AWG7 6mm²/AWG9
Recommended battery capacity 50~450Ah 50~300Ah
AC
Input voltage range 180~250VAC (90~140VAC) 180~250VAC (90~140VAC)
Frequency 50/60Hz 50/60Hz
Full load consumption (230VAC) 419VA 336VA
AC cable 3x0.75 mm² 3x0.75 mm²
Power factor / cos phi 0.99 0.99
General
Ambient operating temperature Guaranteed operation: 0°C to 60°C (derating above +40°C, 5% per °C); in
practice: -20°C to 60°C
Storage temperature -25°C to 85°C
Operating humidity 95% max., non-condensing
Efficiency 90% (at nominal input voltage)
Cooling Variofan ‘low noise’
Protections
Short circuiting Yes
Over heating Limited power by temperature sense circuit
Protection degree IP21
Options
Communication Quasi RS232, modular RJ12 connection, to alter set points and to change
characteristics (optional interface required) or to connect a temperature
sensor and/or remote panel.
Suitable as power supply without battery Yes, in the Forced to float mode.
Mechanical
Connections input/output Screw terminals, maximum wire size 16mm² / AWG 5
Dimensions (HxWxD) 228 x 153 x 82 mm; 8.9 x 6.1 x 3.2 inch
Mounting holes Diameter 5mm
Weight 2.4 kg / 3.9 lbs
Cabinet Anodized aluminium, strapton ABS blend, blue RAL 5021
Directives: - Generic emission and disturbances standard: EN 55014-1:1993
- Generic harmonic current emissions: EN61000-3-3:1995
- Generic & safety accreditations immunity standard: EN55014-2: 1997
- Electrostatic discharge : EN61000-4-2:1995
- Electrical fast transients: EN61000-4-4:1995
- Surge transient: EN61000-4-5:1995
- Conducted radio frequency disturbances: EN61000-4-6:1996
- Voltage dips: EN61000-4-11:1994
Set points software Default setting Set points software Default setting
Max. bulk/abs time 360min. Gel voltage setting 550mV
Return amps 2/16 of I-max Diode compensation setting 600mV
Abs voltage 14.25/28.50VDC DC alarm voltage 12.50/25.00VDC
Float voltage 13.25/26.50VDC DC alarm delay 30s
Forced to float 13.25/26.50VDC