AC Master 12-700 Datasheet

Specifications
General specifications
Output voltage 100/110/115/120 V - 50/60 Hz (selectable)
Output waveform true sine
Nominal battery voltage 12 V
Recommended battery capacity >= 100 Ah
Continuous power at 25 °C / 77 °F, cos phi 1 700 W
Continuous power at 40 °C / 104 °F, cos phi 1 700 W
Peak load (1 min.) < 810 W
Peak load (1 s) < 1230 W
AC connection North American socket with GFCI
Galvanic isolation yes
Efficiency 91 %
Display/read-out LED indication: battery voltage, load level, status
Alarms potential free alarm contact
Dimensions, hxwxd 200 x 330 x 83 mm
7.9 x 13.0 x 3.3 inch
Weight 2,6 kg
5.7 lb
Compliance safety: UL 458, EMC: FCC class B
Technical specifications
Technology high frequency, input & output fully isolated
Low battery voltage, switches off at 10,5 V
Low battery voltage, switches on at 12,5 V
High battery voltage, switches off at 16,5 V
High battery voltage, switches on at 14,5 V
Input current (nominal load) 70 A
No-load power consumption (ON mode) < 1,5 A
No-load power consumption (energy saving mode) < 0,1 A
Minimal DC fuse (slow blow) 100 A
Minimal cable size 25 mm²
Harmonic distortion typical < 5 %
Cos phi all power factors allowed
Temperature range (ambient temp.) -20 °C to 60 °C, derating power > 40 °C
-4 to 140 °F
Cooling temperature and load controlled fan
Protection degree IP21, horizontal wall mounting
Protections over-temperature, overload, short circuit, high/low voltage, reverse
polarity (fuse)
MasterBus compatible yes, using a MasterBus AC Master Interface