Installation Instructions
Page 11
CHARGING A HOT
BATTERY PACK
If the battery pack is above the normal
temperature range, the red LED will illuminate
and the green LED will be off. When the
battery pack cools down to approximately
131°F (55°C) for a Lithium-Ion battery or
104°F (40°C) for a Ni-Cd battery the charger
will automatically begin charging.
CHARGING A COLD
BATTERY PACK
If the battery pack is below the normal
temperature range, the red LED will
illuminate and the green LED will be off.
When the battery warms to a temperature of
more than 38°F (3°C) for a
Lithium-Ion battery or 41°F (5°C) for a Ni-Cd
battery, the charger will automatically begin
charging.
DEFECTIVE BATTERY
If the charger detects a problem, the red
LED will begin flashing and the green LED
will be off.
1. If registering as defective, remove and
reinsert the battery pack in the charger.
If the LED status reads “defective” a
second time, try to charge a different
battery pack.
2. If a different battery pack charges
normally, dispose of the defective
battery pack (see Maintenance section).
3. If a different battery pack also indicates
“defective,” the charger may be
defective.
BATTERY CHARGING
If the battery pack is within the normal
temperature range, the green LED will begin
flashing and the red LED will be off.
BATTERY FULL
After the battery is fully charged, the green
LED Light on the charger will be on and the
red LED light will be off.
NOTICE: The battery pack will fully charge,
but will not overcharge, if left on the
charger.
NOTICE: Charger may warm with several
continuous charge cycles. This is part of
the normal operation of the charge. Charge
in a well ventilated area.
OPERATION