Operating instructions
Long term preservation of
seepex Progressive cavity pumps
Dokument / document
TI.114.01e
Ausgabe / issue
D / 07.05.08
Blatt / sheet
1 (3)
1 Scope
Size Period of Storing Preservation acc. to.
> 3 months ≤ 9 months Measures for preservation 1025-12 ... 130-6L
> 9 months Measures for preservation 2
> 3 months ≤ 9 months Measures for preservation 1130-12 ... 500-6L
> 9 months Measures for preservation 2
2 Description
2.1 Measures for preservation 1
2.1.1 Storing of the pump
• in dry and closed rooms
• free from vibration
Particular adjacent influences have to be advised by the customer and have to be
checked and released by seepex before storage.
2.1.2 Protection of the stator
change the position of the once per month:
• Remove fan cover on the electric motor.
• Rotate the fan shaft 1/4 turn.
Fan shaft and fan must not be damaged! If necessary remove the fan and protect the shaft
against damage during this procedure.
2.1.3 Gear
Note instruction of the manufacturer.
• Follow advice on the gear.
• Reduce quantity of lubricant to the quantity stipulated for the operation
before commissioning!
• Reinstall vent screw during commissioning.
Belt Variable Speed Drive:
Store the belt separate (relevant standard ISO 2230):
• dry
• constant tempered at 10-15°C (max. 25°C)
• protected against light / stored in darkness (e.g. in a closed case or packed accordingly)
2.1.4 Motor
By the turn of the fan shaft (see point 2.1.2) a protection of the bearing in the motor is
obtained at the same time.
41