Operating instructions
9.1
Demontage/
Wiedermontage
Pumpe
Ausgabe
issue
A / 23.01.07
Dokument
document
OM.MAI.99e
Blatt
sheet
3 (4)
9.1.3 Reassembly
WARNING
Tilting or falling pump/pump parts
Injuries and/or damage to equipment. Death or series
injury may result.
Secure the pump.
CAUTION
Danger of fingers being crushed
Slight injury may result.
Do not grasp between connections.
9.1.3.1 Plug in Shaft (307) – reassembly
Clean the flange mechanism surfaces (FLS) and
output pivots of the drive (ANT).
FLS
ANT
Slide on plug in shaft (307).
Tool (W26/assembly
mandrel)
Insert the plug in shaft pin (309) into the plug in
shuft with tool (W26).
309307 W26
9.1.3.2 Mechanical Seal (SEA) - reassembly
Tool (W27/Mounting sleeve with
assembly mandrel)
Gleitringdichtungs-Aufnahme (333),
Gleitringdichtung (SEA) und Stellring (372) auf
Steckwelle (307) schieben.
Secure Mechanical Seal (SEA) with tool (W27)..
SEA372 307W27 333
Tighten the set collar (372) with set screws (378).
378 372
17