Operating instructions

9.1
Demontage/
Wiedermontage
Pumpe
Ausgabe
issue
A / 23.01.07
Dokument
document
OM.MAI.99e
Blatt
sheet
1 (4)
Range: BW
Size: 5-10
9.1.1 Prepare the pump for dismantling
DANGER
Dangerous voltage.
Death or serious injury will result.
Heed safety regulations.
Disconnect pump from all sources of energy.
Secure electrical connections against restarting.
Empty pipes.
Allow pipes to cool down.
Remove pipe connections (suction
side/pressure side).
Heed decommissioning (Chapter 6._).
9.1.2 Demontage
WARNING
Tilting or falling pump
Injuries and/or damage to equipment. Death or
serious injury can result.
Secure the pump.
9.1.2.1 Druckstutzen (700) – Demontage
Dismantle pressure branches (700).
602 606 604700
9.1.2.2 Stator (601) – dismantling
Remove stator (601) from suction casing (500).
601 500
15