Owner's Manual
4
INSTALLATIONPROCEDURES
WARNING:Donotconnectelectricalpowertotheunituntiltheinstallationiscompleted.
TheMasterCoolMCP44coolercanbeinstalledinasash‐styleoraslider‐stylewindow.
Alternatively,thisunitisapprovedforin‐wallinstallations.
Inallinstallations,thefollowingclearancesarerequired:
Width:22”;Height:22”
4”clearanceabovetheexteriorcabinetisneededformaintenance.
NOTE:Ensurethelocationselectedforinstallingtheunitisstrongenoughtosupporttheunitandwillaccept
themountinghardware.Theoperatingweightofthecooleris93pounds.
NOTE:Aminimumoftwopeopleisrequiredfor
installation.
PartsIncluded:
CoolerUnit
Mountingbrackets(4)
Accordionspacers(2)Hardwarekit
Tools&MaterialsRequired:
Drill(powerorcordless)
Assorteddrillbits(fordrillingpilotholesformountinghardware)
AdjustableWrench
PhillipsHeadScrewdriver
Siliconeorall‐weathercaulkforsealinginfillpan eltowindowframe
Lengthof¼”copperorplastictubing
Sillcockvalve
Bubblelevel
spacermaterial(asrequired)
CoolerAssembly
Removeunitfrombox.Verifythatallpartsareincluded.
1. Removeallpackingmaterials.
CALL1‐800‐643‐8341IFYOUFINDPARTSMISSINGORHAVEANYQUESTIONS
2. Withtheunitinanuprightposition,remove4screwsholdingthebackmediaguard,andseparatethefront
andbacksections.Pullthefanassemblyforward(about6”)untilitisfullyengagedwiththematingpart
andsecureinplaceusingthe12suppliedscrews.Verifythatassembly
issecuretopreventvibration
betweenthetwosections
.
EXTEND HOUSING AND
ATTACH IT TO
COOLER BODY FRONT
WITH 12 SCREWS
1. REMOVE 4 SCREWS FROM
BACK MEDIA GUARD
2. PUSH UP ON BACK GUARD
3. PULL BACK GUARD
AWAY FROM UNIT
OPEN UNIT UP
SECURE FAN HOUSING