Specification
9
DIMENSIONAL DATA*
CABINET
DUCT
OPENING
DUCT LOCATION
DRAIN
LOCATION
WET
MOD
ULE
MEDIA
DIMEN
SION
WATER
SERVICE
ELECTRIC
SERVICE
SKID
LOCATIONS
HW D A B C
(AS)
U
(AD)
P
(AU)
EFG J XYLMSTNQR
54 93
-
1
/
4
48
-
1
/
4
26
-
7
/
8
26
-
7
/
8
16
-
13
/
16
19
-
5
/
32
N/A
10 -
11
/
16
24
-
1
/
8
16
-
1
/
2
22
-
1
/
2
48 46
-
3
/
8
5
-
7
/
8
18
-
5
/
8
45
-
1
/
2
5
-
5
/
32
27
-
1
/
4
4
-
3
/
4
52
* All measurements in inches.
PUMP P/N VOLTS AMPS WATTS GPM (5FT. HEAD) BLOWER AND WET MODULE PART NUMBERS
110467 115 1.0 73 4.6 SIDE DISCHARGE BLOWER MODULE AS150B
110468 230 0.58 77 4.6 DOWN DISCHARGE BLOWER MODULE AD150B
2 Pumps Required. WET MODULE AS/AD15012W
SPECIFICATIONS PERFORMANCE
Certified Air Delivery At .1” Increments Of External Static Pressure (Inches Static Pressure Water Gauge)
MAX
B.H.P.
OPER.
WGT
AD
BELT
AS
BELT
0" 0.1" 0.2" 0.3" 0.4" 0.5" 0.6" 0.7" 0.8" 0.9" 1.0"
CFM RPM CFM RPM CFM RPM CFM RPM CFM RPM CFM RPM CFM RPM CFM RPM CFM RPM CFM RPM CFM RPM
2
967 B90 B96 11375 303 10905 314 10482 324 10079 335 9678 346 9265 356 8830 368 8366 380 7867 394 7325 409 6753 426
3
980 B92 B100 13020 346 12604 356 12225 365 11865 375 11514 384 11165 393 10807 403 10440 413 10058 423 9651 433 9220 445
5
996 B93 B100 15438 410 15084 419 14749 427 14434 435 14133 443 13838 450 13540 458 13246 466 12899 474 12640 482 12328 490
7-1/2
1032 B95 B101
17672
470
17360
477
17060
484
16777
491 16505 498 16242 505 15983 512 15724 519 15463 526 15207 532 14947 539
Performance certifi ed is for installation type B - Free inlet, Ducted outlet. Power rating (BHP) does not include transmission losses. Performance ratings do not include the effects of appurtenances
(accessories). Models AS/AD 15012 include the affects of an 12 inch thick evaporative media on the inlet. When the Cooler Model No, Motor H.P. , & Blower Speed are determined from the
SPECIFICATION table above, use this information to select the proper pulley-belt kit from the SHEAVE SELECTION table below.
MOTOR SPECIFICATIONS
BLOWER MOTORS
VOLTS PHASE
MOTOR
AMPS*
SHAFT
DIA.
MOTOR
WGT(LB)
MOTOR
PART NO.
BLOWER MOTORS
VOLTS PHASE
MOTOR
AMPS*
SHAFT
DIA.
MOTOR
WGT(LB)
MOTOR
PART NO.
H.P. SPEED H.P. SPEED
21
115/208-230
1
24/13.2-12
5/8 49 110460-1 3 1
230/460
3
9.6/4.8
1-1/8 83 110465-9
21
200
3
7.8
7/8 44 110464-92 5 1
200
3
17.5
1-1/8 87 110466-92
21
230/460
3
6.8/3.4
7/8 44 110464-9 5 1
230/460
3
15.2/7.6
1/1/8 87 110466-9
31
200
3
11
1-1/8 83 110465-92 7-1/2
1 200 3 25 1-3/8 121 110470-92
7-1/2 1 230/460 3 22/11 1-3/8 121 110470-9
*Amperage shown is from National Electrical Code. Use amperage shown on motor nameplate to determine motor protector.
SHEAVE SELECTION
MOTOR
H.P.
MAUREY
SHEAVE
SHEAVE
BORE
AD
MODEL
BELT
AS
MODEL
BELT
BLOWER RPM/MOTOR SHEAVE 1/2 TURN DOWN
CHAMPION-AD
PULLEY-BELT
KIT NO.
CHAMPION-AS
PULLEY-BELT
KIT NO.
121110987654321
2
D8400 5/8* B90 B96 291 299 308 316 325 333 342 350 359 367 376 384 3DI-51 3DI-71
2
D8450 5/8* B90 B96 347 356 364 373 381 390 398 407 415 424 432 441 3DI-53 3DI-73
2
D8400 7/8* B90 B96 291 299 308 316 325 333 342 350 359 367 376 384 3DI-50 3DI-70
2
D8450 7/8* B90 B96 347 356 364 373 381 390 398 407 415 424 432 441 3DI-52 3DI-72
3
D8450 1-1/8 B92 B100 347 356 364 373 381 390 398 407 415 424 432 441 3DI-56 3DI-75
5
D8550 1-1/8 B93 B100 403 412 420 429 437 446 454 463 471 480 488 497 3DI-60 3DI-80
7-1/2
D8600 1-3/8 B95 B101 459 468 476 485 493 502 510 519 527 536 544 553 3DI-65 3DI-86
*When selecting motor, be sure to select Pulley-Belt Kit with same pulley bore as shaft size of motor selected.
SIZING TABLES
OUTDOOR
DRY BULB
TEMP.
2 H.P. MOTOR / CFM-SP* 3 H.P. MOTOR / CFM-SP* 5 H.P. MOTOR / CFM-SP* 7 H.P. MOTOR / CFM-SP*
11375/ 0 9265 / .5 6753 /1.0 13020 / 0 11165 / .5 9220 /1.0 15438 / 0 13838 / .5 12328/ 1.0 17672 /.1 16242 / .5 14947/ 1.0
OUTDOOR WET-BULB OUTDOOR WET-BULB OUTDOOR WET-BULB OUTDOOR WET-BULB
75
65 55
75 65 55 75 65 55 75
65 55
75 65 55 75 65 55 75
65 55
75 65 55 75 65 55 75
65 55
75 65 55 75 65 55
85
LAT
GPH
76
12
67
25
58
37
76
10
67
20
58
30
76
8
67
15
57
23
76
14
67
28
58
42
76
12
67
24
58
36
76
10
67
20
58
30
76
16
67
33
58
49
76
15
67
30
58
45
76
13
67
27
58
40
76
17
67
33
59
50
76
17
67
35
59
32
76
16
67
32
58
48
95
LAT
GPH
77
25
68
37
59
49
77
20
68
30
59
40
77
15
67
23
58
30
77
28
68
42
59
56
77
24
68
36
59
48
77
20
68
30
59
40
77
33
68
49
60
66
77
30
68
45
59
59
77
27
68
40
59
53
77
33
69
50
60
67
77
33
69
52
60
69
77
32
68
48
60
64
105
LAT
GPH
78
37
69
49
–
–
78
30
68
40
–
–
77
23
68
30
–
–
78
42
69
56
–
–
78
36
69
48
–
–
79
30
69
40
–
–
78
49
70
66
–
–
78
45
69
59
–
–
78
40
69
53
–
–
79
50
70
67
–
–
79
52
70
69
–
–
78
48
70
64
–
–
115
LAT
GPH
79
49
70
61
–
–
79
40
70
51
–
–
78
30
69
38
–
–
79
56
70
70
–
–
79
48
70
60
–
–
79
40
70
50
–
–
80
66
71
82
–
–
79
59
70
74
–
–
79
53
70
67
–
–
80
67
71
83
–
–
80
69
71
87
–
–
80
64
71
80
–
–
*Static pressure (inches of water). GPH = water consumption at design conditions but does not include bleed-off amount. Amount of bleed-off will vary with different water
sources, but an amount equal to 10% of water consumption at any design condition suffi cient for average water. LAT=Cooler Discharge Temperature
.
COMMERICAL SPECIFICATIONS GUIDE
Series AS/AD 15012
AD OUTLET
EEA
Q
X
D
G
F
G
D
S
Q
W
R
C
J
J
N
P
B
B
A
L
MM
E
E
N
Y
L
P
D
H
U
B
T
AD OUTLET
C
TOP VIEW
WEIV EDISWEIV TNORF
BLOWER
SECTION
AS OUTLET
AU OUTLET