Specification

8
DIMENSIONAL DATA*
CABINET
DUCT
OPENING
DUCT LOCATION
DRAIN
LOCATION
WET
MODULE
MEDIA
DIMEN
SION
WATER
SERVICE
ELECTRIC
SERVICE
SKID
LOCATIONS
HW D A BC
(SAS)
U
(SAD)
P
(SAD)
EFGJ XYLMSTNQR
54 66 -
5
/
8
48 -
1
/
4
26 -
7
/
8
26 -
7
/
8
16 -
13
/
16
19 -
5
/
32
2 -
7
/
32
10 -
11
/
16
24 -
1
/
8
12-
1
/
2
18 -
1
/
2
48 46 -
3
/
8
5 -
7
/
8
14 -
5
/
8
23 -
1
/
8
5 -
5
/
32
4 -
3
/
4
4 -
3
/
4
52
* All measurements in inches.
PUMP P/N VOLTS AMPS WATTS GPM (5FT. HEAD) BLOWER AND WET MODULE PART NUMBERS
110467 115 1.0 73 4.6 SIDE DISCHARGE BLOWER MODULE SAS150B
110468 230 0.58 77 4.6 DOWN DISCHARGE BLOWER MODULE SAD150B
1 Pump Required. WET MODULE SAS/SAD150W
SPECIFICATIONS PERFORMANCE
Certified Air Delivery At .1” Increments Of External Static Pressure (Inches Static Pressure Water Gauge)
MAX
B.H.P.
OPER.
WGT.
SAD
MODEL
BELT
SAS
MODEL
BELT
0" 0.1" 0.2" 0.3" 0.4" 0.5" 0.6" 0.7" 0.8" 0.9" 1.0"
CFM RPM CFM RPM CFM RPM CFM RPM CFM RPM CFM RPM CFM RPM CFM RPM CFM RPM CFM RPM CFM RPM
3/4
584 B90 B96 7072 275 6622 287 6203 298 5769 308 5298 321 4777 336 4201 355 3607 378 3041 402 2522 424 2040 443
1
593 B90 B96 7783 302 7372 314 6987 324 6602 333 6199 343 5764 355 5285 369 4764 386 4231 406 3699 427 3199 448
1-1/2
608 B90 B96 8910 346 8548 356 8205 365 7870 374 7533 382 7182 391 6812 401 6416 412 5993 424 5537 439 5067 456
2
612 B90 B96
N/A
N/A
9476
390
9159
399
8855
406 8555 414 8244 421 7924 430 7592 438 7236 448 6866 459 6470 471
3
624 B92 B100 N/A N/A N/A N/A N/A N/A N/A N/A N/A N/A N/A N/A N/A N/A 9315 486 9032 493 8741 500 8436 509
Performance certi ed is for installation type B - Free inlet, Ducted outlet. Power rating (BHP) does not include transmission losses. Performance ratings do not include the effects of appurtenances (accessories).
Models SAS/SAD 150 include the affects of an 8 inch thick evaporative media on the inlet. When the Cooler Model No., Motor H.P. , & Blower Speed are determined from the SPECIFICATION table above,
use this information to select the proper pulley-belt kit from the SHEAVE SELECTION table below.
MOTOR SPECIFICATIONS
BLOWER MOTORS
VOLTS PHASE
MOTOR
AMPS*
SHAFT
DIA.
MOTOR
WGT(LB)
MOTOR
PART NO.
BLOWER MOTORS
VOLTS PHASE
MOTOR
AMPS*
SHAFT
DIA.
MOTOR
WGT(LB)
MOTOR
PART NO.
H.P. SPEED H.P. SPEED
3/4 1
115/208-230
1
13.8/7.6-6.9
5/8 24 110455 1-1/2 1
200
3
6.9
7/8 40 110463-92
3/4 2
230
1
6.9
5/8 29 110456 1-1/2 1
230/460
3
6/3
7/8 40 110463-9
3/4 1
208-230/460
3
3.5-3.2/1.6
5/8 20 110461 2 1
115/208-230
1
24/13.2-12
5/8 49 110460-1
11
115/230
1
16/8
5/8 28 110457
2 1 200 3 7.8 7/8 44 110464-92
12
230
1
8
5/8 29 110458 2 1
230/460
3
6.8/3.4
7/8 44 110464-9
11
200
3
4.8
7/8 34 110462-92 3 1
200
3
11
1-1/8 83 110465-92
11
230/460
3
4.2/2.1
7/8 34 110462-9 3 1
230/460
3
9.6/4.8
1-1/8 83 110465-9
1 1/2 1
115/208-230
1
20/11-10
5/8 41 110459-1
*Amperage shown is from National Electrical Code. Use amperage shown on motor nameplate to determine motor protector.
SHEAVE SELECTION
MOTOR
H.P.
MAUREY
SHEAVE
SHEAVE
BORE
SAD
MODEL
BELT
SAS
MODEL
BELT
BLOWER RPM/MOTOR SHEAVE 1/2 TURN DOWN
CHAMPION-SAD
PULLEY-BELT
KIT NO.
CHAMPION-SAS
PULLEY-BELT
KIT NO.
121110987654321
3/4, 1
8350K 5/8* B90 B96 253 261 269 278 287 296 304 313 321 330 338 347 3DI-130 3DI-165
3/4, 1, 1-1/2, 2
8450K 5/8* B90 B96 347 356 364 373 381 390 398 407 415 424 432 441 3DI-135 3DI-170
2
8550 5/8 B90 B96 403 412 420 429 437 446 454 463 471 480 488 497 3DI-156 3DI-186
1
8350 7/8* B90 B96 253 261 269 278 287 296 304 313 321 330 338 347 3DI-140 3DI-175
1, 1-1/2, 2
8450K 7/8* B90 B96 347 356 364 373 381 390 398 407 415 424 432 441 3DI-145 3DI-180
1-1/2, 2
8550 7/8 B90 B96 403 412 420 429 437 446 454 463 471 480 488 497 3DI-155 3DI-185
3
8550 1-1/8 B92 B100 403 412 420 429 437 446 454 463 471 480 488 497 3DI-161 3DI-190
*When selecting motor, be sure to select Pulley-Belt Kit with same pulley bore as shaft size of motor selected.
SIZING TABLES
OUTDOOR
DRY BULB
TEMP.
3/4 H.P. MOTOR / CFM-SP* 1 H.P. MOTOR / CFM-SP* 1-1/2 H.P. MOTOR / CFM-SP* 2 H.P. MOTOR / CFM-SP* 3 H.P. MOTOR / CFM-SP*
7072 / 0 4777 / .5 2040 /1.0 7783 / 0 5764 / .5 3199 /1.0 8910 / 0 7182 / .5 5067 / 1.0 9476 /.1 8244 / .5 6470 / 1.0 9315 / .7 8436 / 1.0
OUTDOOR WET-BULB OUTDOOR WET-BULB OUTDOOR WET-BULB OUTDOOR WET-BULB OUTDOOR WET-BULB
75
65 55
75 65 55 75 65 55 75
65 55
75 65 55 75 65 55 75
65 55
75 65 55 75 65 55 75
65 55
75 65 55 75 65 55 75
65 55
75 65 55 75 65 55
85
LAT
GPH
77
7
69
14
61
21
77
5
68
9
60
14
76
2
68
5
59
7
77
8
69
15
62
23
77
6
69
11
61
17
76
3
68
7
59
10
78
8
70
17
62
25
77
7
69
14
61
20
77
5
68
9
60
14
77
9
70
17
62
26
77
8
70
15
62
23
77
6
69
12
61
18
77
9
70
17
62
26
77
8
70
15
62
23
95
LAT
GPH
79
14
71
21
63
28
78
9
70
14
62
18
78
5
69
7
61
9
79
15
72
23
64
30
79
11
71
17
62
22
78
7
69
10
61
14
80
17
72
25
64
34
79
14
71
20
63
27
79
9
70
14
62
19
80
17
72
26
64
34
80
15
72
23
64
31
79
12
71
18
63
24
80
17
72
26
64
34
80
15
72
23
64
31
105
LAT
GPH
81
21
73
28
80
14
72
18
79
7
71
9
82
23
74
30
81
17
72
22
79
10
71
14
82
25
74
34
81
20
73
27
80
14
72
19
82
26
74
34
82
23
74
31
81
18
73
24
82
26
74
34
82
23
74
31
115
LAT
GPH
83
28
75
35
82
18
73
23
81
9
72
11
84
30
76
38
82
22
74
28
81
14
72
17
84
34
77
42
83
27
75
34
82
19
73
23
84
34
77
43
84
31
76
39
83
24
75
30
84
34
77
43
84
31
76
39
*Static pressure (inches of water). GPH = water consumption at design conditions but does not include bleed-off amount. Amount of bleed-off will vary with different water sources, but an
amount equal to 10% of water consumption at any design condition suf cient for average water. LAT=Cooler Discharge Temperature.