Specification

6
DIMENSIONAL DATA*
CABINET
DUCT
OPENING
DUCT LOCATION
DRAIN
LOCATION
WET
MOD
ULE
MEDIA
DIMEN
SION
WATER
SERVICE
ELECTRIC
SERVICE
SKID
LOCATIONS
HW D A B C
(SAS)
U
(SAD)
P
(SAD)
EFG J XYLMSTNQR
44 67 -
3
/
8
45 21-
3
/
4
21-
3
/
4
13 -
19
/
32
21-
11
/
32
1 -
29
/
32
11-
5
/
8
22 -
1
/
2
16 -
1
/
2
22 -
1
/
2
44 -
3
/
4
36
-
5
/
8
5
-
7
/
8
18
-
5
/
8
21 -
1
/
2
5 -
5
/
32
4 -
3
/
4
4 -
3
/
4
42
* All measurements in inches.
PUMP P/N VOLTS AMPS WATTS GPM (5FT. HEAD) BLOWER AND WET MODULE PART NUMBERS
110467 115 1.0 73 4.6 SIDE DISCHARGE BLOWER MODULE SAS100B
110468 230 0.58 77 4.6 DOWN DISCHARGE BLOWER MODULE SAD100B
1 Pump Required. WET MODULE SAS/SAD10012W
SPECIFICATIONS PERFORMANCE
Certified Air Delivery At .1” Increments Of External Static Pressure (Inches Static Pressure Water Gauge)
MAX
B.H.P.
OPER.
WGT.
SAD
MODEL
BELT
SAS
MODEL
BELT
0" 0.1" 0.2" 0.3" 0.4" 0.5" 0.6" 0.7" 0.8" 0.9" 1.0"
CFM RPM CFM RPM CFM RPM CFM RPM CFM RPM CFM RPM CFM RPM CFM RPM CFM RPM CFM RPM CFM RPM
3/4
527 B77 B83 5371 362 5064 374 4794 386 4536 397 4269 410 3985 423 3667 439 3318 458 2952 481 2591 507 2261 534
1
530 B77 B83 5911 359 5627 410 5375 420 5142 431 4907 441 4663 453 4399 465 4115 479 3809 495 3480 514 3145 536
1-1/2
545 B77 B83 6767 457 6513 466 6286 475 6076 484 5872 494 5666 503 5456 513 5238 523 5008 534 4755 546 4497 560
Performance certi ed is for installation type B - Free inlet, Ducted outlet. Power rating (BHP) does not include transmission losses. Performance ratings do not include the effects of ap-
purtenances (accessories). Models SAS/SAD 10012 include the affects of an 12 inch thick evaporative media on the inlet. When the Cooler Model No, Motor H.P. , & Blower Speed
are determined from the SPECIFICATION table above, use this information to select the proper pulley-belt kit from the SHEAVE SELECTION table below.
MOTOR SPECIFICATIONS
BLOWER MOTORS
VOLTS PHASE
MOTOR
AMPS*
SHAFT
DIA.
MOTOR
WGT(LB)
MOTOR
PART NO.
BLOWER MOTORS
VOLTS PHASE
MOTOR
AMPS*
SHAFT
DIA.
MOTOR
WGT(LB)
MOTOR
PART NO.
H.P. SPEED H.P. SPEED
3/4 1
115/208-230
1
13.8/7.6-6.9
5/8 24 110455 1 1
200
3
4.8
7/8 34 110462-92
3/4 2
230
1
6.9
5/8 29 110456 1 1
230/460
3
4.2/2.1
7/8 34 110462-9
3/4 1
208-230/460
3
3.5-3.2/1.6
5/8 20 110461 1 1/2 1
115/208-230
1
20/11-10
5/8 41 110459-1
11
115/230
1
16/8
5/8 28 110457 1-1/2 1
200
3
6.9
7/8 40 110463-92
12
230
1
8
5/8 29 110458 1-1/2 1
230/460
3
6/3
7/8 40 110463-9
*Amperage shown is from National Electrical Code. Use amperage shown on motor nameplate to determine motor protector.
SHEAVE SELECTION
MOTOR
H.P.
MAUREY
SHEAVE
SHEAVE
BORE
SAD
MODEL
BELT
SAS
MODEL
BELT
BLOWER RPM/MOTOR SHEAVE 1/2 TURN DOWN
CHAMPION-SAD
PULLEY-BELT
KIT NO.
CHAMPION-SAS
PULLEY-BELT
KIT NO.
121110987654321
3/4, 1
8350K 5/8* B77 B83 303 313 323 333 343 353 364 374 384 394 404 414 3DI-90 3DI-110
3/4, 1, 1-1/2
8450K 5/8* B77 B83 414 424 434 445 455 465 475 485 495 506 516 526 3DI-95 3DI-115
1
8350 7/8* B77 B83 303 313 323 333 343 353 364 374 384 394 404 414 3DI-100 3DI-120
1, 1-1/2
8450K 7/8* B77 B83 414 424 434 445 455 465 475 485 495 506 516 526 3DI-105 3DI-125
*When selecting motor, be sure to select Pulley-Belt Kit with same pulley bore as shaft size of motor selected.
SIZING TABLES
OUTDOOR
DRY BULB
TEMP.
3/4 H.P. MOTOR / CFM-SP* 1 H.P. MOTOR / CFM-SP* 1-1/2 H.P. MOTOR / CFM-SP*
5371 / 0 3985 / .5 2261 /1.0 5911 / 0 4663 / .5 3145 /1.0 6767 / 0 5666/ .5 4497 / 1.0
OUTDOOR WET-BULB OUTDOOR WET-BULB OUTDOOR WET-BULB
75
65 55
75 65 55 75 65 55 75
65 55
75 65 55 75 65 55 75
65 55
75 65 55 75 65 55
85
LAT
GPH
76
6
67
12
58
17
76
6
67
12
58
13
76
2
66
5
57
7
76
6
67
13
58
19
76
6
67
13
58
19
76
5
67
10
58
16
76
7
67
14
59
22
76
6
67
12
58
18
76
6
67
10
58
15
95
LAT
GPH
77
12
68
17
59
23
77
12
68
17
59
23
76
5
67
7
58
9
77
13
68
19
59
25
77
10
68
15
59
20
77
7
68
10
58
13
77
14
69
22
60
29
77
12
68
18
60
25
77
10
68
15
59
19
105
LAT
GPH
78
17
69
23
78
12
69
16
77
7
68
9
78
19
69
25
78
15
69
20
78
10
68
13
79
22
70
29
78
18
70
25
78
15
69
19
115
LAT
GPH
79
23
70
29
79
16
70
20
78
9
68
11
79
25
71
32
79
20
70
25
78
13
69
16
80
29
71
36
80
25
71
31
79
19
70
24
*Static pressure (inches of water). GPH = water consumption at design conditions but does not include bleed-off amount.
Amount of bleed-off will vary with different water sources, but an amount equal to 10%
of water consumption at any design condition suf cient for average water
.
LAT=Cooler Discharge Temperature.
COMMERICAL SPECIFICATIONS GUIDE
Series SAS/SAD 10012
Q
D
E
E
A
F
G
X
D
S
Q
D
C
R
C
N
B
A
E
E
N
T
W
H
U
BP
W
J
L
Y
M
J
SAD OUTLETSAD OUTLET
SAS
OUTLET
TOP VIEW
WEIV EDISWEIV TNORF