Specification

5
DIMENSIONAL DATA*
CABINET
DUCT
OPENING
DUCT LOCATION
DRAIN
LOCATION
WET
MOD
ULE
MEDIA
DIMENSION
WATER
SERVICE
ELECTRIC
SERVICE
SKID
LOCATIONS
HW D A B C
(AS)
U
(AD)
P
(AU)
EFG JXYLMSTNQR
44 90 45 21
-
3
/
4
21
-
3
/
4
13-
19
/
32
21
-
11
/
32
N/A 11
-
5
/
8
22
-
1
/
2
16
-
1
/
2
22
-
1
/
2
44
-
3
/
4
36
-
5
/
8
5
-
7
/
8
18
-
5
/
8
43
-
7
/
8
5
-
5
/
32
27
-
1
/
4
4
-
3
/
4
42
* All measurements in inches.
PUMP P/N VOLTS AMPS WATTS GPM (5FT. HEAD) BLOWER AND WET MODULE PART NUMBERS
110467 115 1.0 73 4.6 SIDE DISCHARGE BLOWER MODULE AS100B
110468 230 0.58 77 4.6 DOWN DISCHARGE BLOWER MODULE AD100B
Pumps - 2 Required. WET MODULE AS/AD10012W
SPECIFICATIONS PERFORMANCE
Certified Air Delivery At .1” Increments Of External Static Pressure (Inches Static Pressure Water Gauge)
MAX
B.H.P.
OPER.
WGT.
AD
MODEL
BELT
AS
MODEL
BELT
0" 0.1" 0.2" 0.3" 0.4" 0.5" 0.6" 0.7" 0.8" 0.9" 1.0"
CFM RPM CFM RPM CFM RPM CFM RPM CFM RPM CFM RPM CFM RPM CFM RPM CFM RPM CFM RPM CFM RPM
1 1/2
801 A76 A82 7431 382 7255 390 7052 400 6835 411 6611 424 6376 437 6131 450 5877 464 5610 477 5327 492 5031 507
2
805 B77 B83 8178 421 8024 427 7842 436 7649 446 7450 457 7244 468 7030 480 6809 492 6580 504 6343 517 6095 529
3
818 B80 B86 9362 482 9235 487 9075 494 8914 502 8744 511 8572 520 8393 531 8209 541 8024 551 7827 562 7631 672
5
834 B81 B87
11099
571
11001
575
10868
581
10736
587 10598 594 10457 601 10313 609 10165 617 10016 625 9862 634 9709 643
Performance certi ed is for installation type B - Free inlet, Ducted outlet. Power rating (BHP) does not include transmission losses. Performance ratings do not include the effects of appurtenances
(acces-
sories). Models AS/AD 10012 include the affects of an 12 inch thick evaporative media on the inlet. When the Cooler Model No, Motor H.P. , & Blower Speed are determined from the SPECIFICATION table
above, use this information to select the proper pulley-belt kit from the SHEAVE SELECTION table below.
MOTOR SPECIFICATIONS
BLOWER MOTORS
VOLTS PHASE
MOTOR
AMPS*
SHAFT
DIA.
MOTOR
WGT(LB)
MOTOR
PART NO.
BLOWER MOTORS
VOLTS PHASE
MOTOR
AMPS*
SHAFT
DIA.
MOTOR
WGT(LB)
MOTOR
PART NO.
H.P. SPEED H.P. SPEED
1-1/2 1
115/208-230
1
20/11-10
5/8 41 110459-1 2 1
230/460
3
6.8/3.4
7/8 44 110464-9
1-1/2 1
200
3
6.9
7/8 40 110463-92 3 1
200
3
11.0
1-1/8 83 110465-92
1-1/2 1
230/460
3
6/3
7/8 40 110463-9 3 1
230/460
3
9.6/4.8
1-1/8 83 110465-9
21
115/208-230
1
24/13.2-12
5/8 49 110460-1 5 1 200 3 17.5 1-1/8 87 110466-92
21
200
3
7.8
7/8 44 110464-92 5 1 230/460 3 15.2/7.6 1-1/8 87 110466-9
*Amperage shown is from National Electrical Code. Use amperage shown on motor nameplate to determine motor protector.
SHEAVE SELECTION
MOTOR
H.P.
MAUREY
SHEAVE
SHEAVE
BORE
AD
MODEL
BELT
AS
MODEL
BELT
BLOWER RPM/MOTOR SHEAVE 1/2 TURN DOWN
CHAMPION-AD
PULLEY-BELT
KIT NO.
CHAMPION-AS
PULLEY-BELT
KIT NO.
121110987654321
1-1/2
D8450 5/8* A76 A82 391 401 412 422 433 443 454 464 475 485 496 506 3DI-11 3DI-31
1-1/2
D8450 7/8* A76 A82 391 401 412 422 433 443 454 464 475 485 496 506 3DI-10 3DI-30
2
D8450 5/8* B77 B83 414 424 434 445 455 465 475 485 495 506 516 526 3DI-16 3DI-36
2
D8450 7/8* B77 B83 414 424 434 445 455 465 475 485 495 506 516 526 3DI-15 3DI-35
3
D8550 1-1/8 B80 B86 482 492 502 513 523 533 543 553 563 574 584 594 3DI-20 3DI-40
5
D8600 1-1/8 B81 B87 549 559 569 580 590 600 610 620 630 641 651 661 3DI-25 3DI-45
* When selecting motor, be sure to select Pulley-Belt Kit with same pulley bore as shaft size of motor selected.
SIZING TABLES
OUTDOOR
DRY BULB
TEMP.
1-1/2 H.P. MOTOR / CFM-SP* 2 H.P. MOTOR / CFM-SP* 3 H.P. MOTOR / CFM-SP* 5 H.P. MOTOR / CFM-SP*
7431 / 0 6376 / .5 5031 /1.0 8178 / 0 7244 / .5 6095 /1.0 9362 / 0 8572 / .5 7631 / 1.0 11099 /0 10457 / .5 9709 / 1.0
OUTDOOR WET-BULB OUTDOOR WET-BULB OUTDOOR WET-BULB OUTDOOR WET-BULB
75
65 55
75 65 55 75 65 55 75
65 55
75 65 55 75 65 55 75
65 55
75 65 55 75 65 55 75
65 55
75 65 55 75 65 55
85
LAT
GPH
76
8
67
17
58
25
76
7
67
14
58
21
76
6
67
11
57
17
76
9
67
18
58
28
76
8
67
16
58
24
76
7
67
13
58
20
76
11
67
21
58
32
76
9
67
19
58
28
76
8
67
17
58
25
76
12
67
25
58
37
76
11
67
23
58
34
76
11
67
21
58
32
95
LAT
GPH
77
17
68
25
59
34
77
14
68
21
59
28
77
11
67
17
58
22
77
18
68
28
59
37
77
16
68
24
59
32
77
13
68
20
59
27
77
21
68
32
59
42
77
19
68
28
59
38
77
17
68
25
59
32
77
25
68
37
60
49
77
23
68
34
59
46
77
21
68
32
59
42
105
LAT
GPH
78
25
69
34
78
21
69
28
77
17
68
22
78
28
69
37
78
24
69
32
78
20
69
27
78
32
69
42
78
28
69
38
78
25
69
33
78
37
70
49
78
34
69
46
78
32
69
42
115
LAT
GPH
79
34
70
42
79
28
70
35
78
22
69
28
79
37
70
46
79
32
70
40
79
27
69
33
79
42
70
53
79
38
70
47
79
33
70
42
80
49
71
62
79
46
71
57
79
42
70
53
*Static pressure (inches of water). GPH= Water consumption at design conditions but does not include bleed-off amount. Amount of bleed-off will vary with
different water sources, but an amount equal to 10% of water consumption at any design condition suf cient for average water.
LAT=Cooler Discharge Temperature
.
COMMERICAL SPECIFICATIONS GUIDE
Series AS/AD 10012
AD OUTLET
EEA
Q
X
D
G
F
G
D
S
Q
W
R
C
J
J
N
P
B
B
A
L
MM
E
E
N
Y
L
P
D
H
U
B
T
AD OUTLET
C
TOP VIEW
WEIV EDISWEIV TNORF
BLOWER
SECTION
AS OUTLET
AU OUTLET