Specification

4
DIMENSION AL DATA*
CABINET
DUCT
OPENING
DUCT LOCATION
DRAIN
LOCATION
WET
MODULE
MEDIA
DIMEN
SION
WATER
SERVICE
ELECTRIC
SERVICE
SKID
LOCATIONS
HW D A BC
(SAS)
U
(SAD)
P
(SAD)
EFG J XYLMS T N QR
44 63 -
3
/
8
45 21 -
3
/
4
21 -
3
/
4
13 -
19
/
32
21-
11
/
32
1-
29
/
32
11 -
5
/
8
22 -
1
/
2
12 -
1
/
2
18 -
1
/
2
44 -
3
/
4
36 -
5
/
8
5 -
7
/8
14 -
5
/
8
21-
1
/
2
5 -
5
/
32
4 -
3
/
4
4 -
3
/
4
42
* All measurements in inches.
PUMP P/N VOLTS AMPS WATTS GPM (5FT. HEAD) BLOWER AND WET MODULE PART NUMBERS
110467 115 1.0 73 4.6 SIDE DISCHARGE BLOWER MODULE SAS100B
110468 230 0.58 77 4.6 DOWN DISCHARGE BLOWER MODULE SAD100B
1 Pump Required. WET MODULE SAS/SAD100W
SPECIFICATIONS PERFORMANCE
Certified Air Delivery At .1” Increments Of External Static Pressure (Inches Static Pressure Water Gauge)
MAX
B.H.P.
OPER.
WGT.
SAD
MODEL
BELT
SAS
MODEL
BELT
0" 0.1" 0.2" 0.3" 0.4" 0.5" 0.6" 0.7" 0.8" 0.9" 1.0"
CFM RPM CFM RPM CFM RPM CFM RPM CFM RPM CFM RPM CFM RPM CFM RPM CFM RPM CFM RPM CFM RPM
3/4
480 B77 B83 5377 352 5121 364 4863 376 4605 389 4336 402 4058 415 3754 430 3429 448 3097 469 ---- ---- ---- ----
1
483 B77 B83 5918 388 5684 398 5451 409 5215 421 4980 432 4734 444 4479 456 4209 470 3924 485 3619 503 3307 523
1 1/2
498 B77 B83 6774 444 6574 453 6366 463 6164 472 5956 482 5751 492 5537 502 5320 513 5095 524 4859 536 4613 548
Performance certi ed is for installation type B - Free inlet, Ducted outlet. Power rating (BHP) does not include transmission losses. Performance ratings do not include the effects of appurtenances (accessories).
Models SAS/SAD 100 include the affects of an 8 inch thick evaporative media on the inlet. When the Cooler Model No, Motor H.P. , & Blower Speed are determined from the SPECIFICATION table above,
use this information to select the proper pulley-belt kit from the SHEAVE SELECTION table below.
MOTOR SPECIFICATIONS
BLOWER MOTORS
VOLTS PHASE
MOTOR
AMPS*
SHAFT
DIA.
MOTOR
WGT(LB)
MOTOR
PART NO.
BLOWER MOTORS
VOLTS PHASE
MOTOR
AMPS*
SHAFT
DIA.
MOTOR
WGT(LB)
MOTOR
PART NO.
H.P. SPEED H.P. SPEED
3/4 1
115/208-230
1
13.8/7.6-6.9
5/8 24 110455 1 1
200
3
4.8
7/8 34 110462-92
3/4 2
230
1
6.9
5/8 29 110456 1 1
230/460
3
4.2/2.1
7/8 34 110462-9
3/4 1
208-230/460
3
3.5-3.2/1.6
5/8 20 110461 1-1/2 1
115/208-230
3
20/11-10
5/8 41 110459-1
11
115/230
1
16/8
5/8 28 110457 1-1/2 1
200
3
6.9
7/8 40 110463-92
12
230
1
8
5/8 29 110458 1-1/2 1
230/460
3
6/3
7/8 40 110463-9
*Amperage shown is from National Electrical Code. Use amperage shown on motor nameplate to determine motor protector.
SHEAVE SELECTION
MOTOR
H.P.
MAUREY
SHEAVE
SHEAVE
BORE
SAD
MODEL
BELT
SAS
MODEL
BELT
BLOWER RPM/MOTOR SHEAVE 1/2 TURN DOWN
CHAMPION-SAD
PULLEY-BELT
KIT NO.
CHAMPION-SAS
PULLEY-BELT
KIT NO.
121110987654321
3/4, 1
8350K 5/8* B77 B83 303 313 323 333 343 353 364 374 384 394 404 414 3DI-90 3DI-110
3/4, 1, 1-1/2
8450K 5/8* B77 B83 414 424 434 445 455 465 475 485 495 506 516 526 3DI-95 3DI-115
1
8350 7/8* B77 B83 303 313 323 333 343 353 364 374 384 394 404 414 3DI-100 3DI-120
1, 1-1/2
8450K 7/8* B77 B83 414 424 434 445 455 465 475 485 495 506 516 526 3DI-105 3DI-125
*When selecting motor, be sure to select Pulley-Belt Kit with same pulley bore as shaft size of motor selected.
SIZING TABLES
OUTDOOR
DRY BULB
TEMP.
3/4 H.P. MOTOR / CFM-SP* 1 H.P. MOTOR / CFM-SP* 1-1/2 H.P. MOTOR / CFM-SP*
5377 / 0 4058 / .5 3097/.8 5918 / 0 4734 / .5 3307 /1.0 6774 / 0 5751 / .5 4613 / 1.0
OUTDOOR WET-BULB OUTDOOR WET-BULB OUTDOOR WET-BULB
75
65 55
75 65 55 75 65 55 75
65 55
75 65 55 75 65 55 75
65 55
75 65 55 75 65 55
85
LAT
GPH
77
5
69
10
61
15
77
4
69
8
60
12
76
3
67
6
59
9
77
6
69
11
62
17
77
5
69
9
61
14
77
3
68
7
60
10
77
6
70
13
62
19
77
6
69
11
61
17
77
5
69
9
61
13
95
LAT
GPH
79
10
71
15
63
21
79
8
70
12
62
16
77
6
69
9
60
12
79
11
72
17
64
22
79
9
71
14
63
19
78
7
70
10
61
13
80
13
72
19
64
25
79
11
71
17
64
22
79
9
70
13
63
18
105
LAT
GPH
81
15
73
21
80
12
72
16
79
9
70
12
82
17
74
22
81
14
73
19
80
10
71
13
82
19
74
25
81
17
74
22
81
13
73
18
115
LAT
GPH
83
21
75
26
82
16
74
21
80
12
72
15
84
22
76
28
83
19
75
23
81
13
73
16
84
25
77
32
84
22
76
28
83
18
75
22
*Static pressure (inches of water). GPH = water consumption at design conditions but does not include bleed-off amount.
Amount of bleed-off will vary with different water sources, but an amount equal to 10%
of water consumption at any design condition suf cient for average water.
LAT=Cooler Discharge Temperature.
COMMERICAL SPECIFICATIONS GUIDE
Series SAS/SAD 100
Q
D
E
E
A
F
G
X
D
S
Q
D
C
R
C
N
B
A
E
E
N
T
W
H
U
BP
W
J
L
Y
M
J
SAD OUTLETSAD OUTLET
SAS
OUTLET
TOP VIEW
WEIV EDISWEIV TNORF