Specification
10
DIMENSIONAL DATA*
CABINET
DUCT
OPENING
DUCT LOCATION
DRAIN
LOCATION
WET
MODULE
MEDIA
DIMEN
SION
WATER
SERVICE
ELECTRIC
SERVICE
SKID
LOCATIONS
HWD A BC
(AS)
U
(AD)
P
(AU)
EFG J XYLMSTNQR
54 70 -
5
/
8
48 -
1
/
4
26 -
7
/
8
26 -
7
/
8
16
-
13
/
32
19
-
5
/
32
2
-
7
/
32
10
-
11
/
16
24 -
1
/
8
16 -
1
/
2
22-
1
/
2
48
46 -
3
/
8
5 -
7
/
8
18 -
5
/
8
23 -
1
/
8
5
-
5
/
32
4 -
3
/
4
4 -
3
/
4
52
* All measurements in inches.
PUMP P/N VOLTS AMPS WATTS GPM (5FT. HEAD) BLOWER AND WET MODULE PART NUMBERS
110467 115 1.0 73 4.6 SIDE DISCHARGE BLOWER MODULE SAS150B
110468 230 0.58 77 4.6 DOWN DISCHARGE BLOWER MODULE SAD150B
1 Pump Required. WET MODULE SAS/SAD15012W
SPECIFICATIONS PERFORMANCE
Certified Air Delivery At .1” Increments Of External Static Pressure (Inches Static Pressure Water Gauge)
MAX
B.H.P.
OPER.
WGT.
SAD
MODEL
BELT
SAS
MODEL
BELT
0" 0.1" 0.2" 0.3" 0.4" 0.5" 0.6" 0.7" 0.8" 0.9" 1.0"
CFM RPM CFM RPM CFM RPM CFM RPM CFM RPM CFM RPM CFM RPM CFM RPM CFM RPM CFM RPM CFM RPM
3/4
645 B90 B96 6997 267 6539 278 6087 289 5603 301 5051 315 4415 332 3717 353 3058 376 2497 398 2013 419 1571 436
1
649 B90 B96 7702 294 7286 303 6876 314 6450 324 5994 336 5477 349 4893 364 4260 383 3637 404 3085 425 2609 444
1-1/2
665 B90 B96 8817 336 8455 345 8091 353 7734 363 7359 372 6961 382 6525 393 6050 405 5527 419 4976 435 4425 453
2
669 B90 B96
N/A
N/A
9375
378
9044
386
8719
394 8389 402 8043 411 7683 420 7293 430 6869 440 6416 452 5932 465
3
681 B92 B100 N/A N/A N/A N/A N/A N/A N/A N/A N/A N/A N/A N/A 9377 466 9070 474 8751 482 8407 490 8046 499
Performance certifi ed is for installation type B - Free inlet, Ducted outlet. Power rating (BHP) does not include transmission losses. Performance ratings do not include the effects of appurtenances
(accessories). Models SAS/SAD 15012 include the affects of an 12 inch thick evaporative media on the inlet. When the Cooler Model No, Motor H.P. , & Blower Speed are determined from the
SPECIFICATION table above, use this information to select the proper pulley-belt kit from the SHEAVE SELECTION table below.
MOTOR SPECIFICATIONS
BLOWER MOTORS
VOLTS PHASE
MOTOR
AMPS*
SHAFT
DIA.
MOTOR
WGT(LB)
MOTOR
PART NO.
BLOWER MOTORS
VOLTS PHASE
MOTOR
AMPS*
SHAFT
DIA.
MOTOR
WGT(LB)
MOTOR
PART NO.
H.P. SPEED H.P. SPEED
3/4 1
115/208-230
1
13.8/7.6-6.9
5/8 24 110455 1-1/2 1
200
3
6.9
7/8 40 110463-92
3/4 2
230
1
6.9
5/8 29 110456 1-1/2 1
230/460
3
6/3
7/8 40 110463-9
3/4 1
208-230/460
3
3.5-3.2/1.6
5/8 20 110461 2 1
115/208-230
1
24/13.2-12
5/8 49 110460-1
11
115/230
1
16/8
5/8 28 110457
2 1 200 3 7.8 7/8 44 110464-92
12
230
1
8
5/8 29 110458 2 1
230/460
3
6.8/3.4
7/8 44 110464-9
11
200
3
4.8
7/8 34 110462-92 3 1
200
3
11
1-1/8 83 110465-92
11
230/460
3
4.2/2.1
7/8 34 110462-9 3 1
230/460
3
9.6/4.8
1-1/8 83 110465-9
1 1/2 1
115/208-230
1
20/11-10
5/8 41 110459-1
*Amperage shown is from National Electrical Code. Use amperage shown on motor nameplate to determine motor protector.
SHEAVE SELECTION
MOTOR
H.P.
MAUREY
SHEAVE
SHEAVE
BORE
SAD
MODEL
BELT
SAS
MODEL
BELT
BLOWER RPM/MOTOR SHEAVE 1/2 TURN DOWN
CHAMPION-SAD
PULLEY-BELT
KIT NO.
CHAMPION-SAS
PULLEY-BELT
KIT NO.
121110987654321
3/4, 1
8350K 5/8* B90 B96 253 261 269 278 287 296 304 313 321 330 338 347 3DI-130 3DI-165
3/4, 1, 1 1/2, 2
8450K 5/8* B90 B96 347 356 364 373 381 390 398 407 415 424 432 441 3DI-135 3DI-170
2
8550 5/8 B90 B96 403 412 420 429 437 446 454 463 471 480 488 497 3DI-156 3DI-186
1
8350 7/8* B90 B96 253 261 269 278 287 296 304 313 321 330 338 347 3DI-140 3DI-175
1, 1 1/2, 2
8450K 7/8* B90 B96 347 356 364 373 381 390 398 407 415 424 432 441 3DI-145 3DI-180
1 1/2, 2
8550 7/8 B90 B96 403 412 420 429 437 446 454 463 471 480 488 497 3DI-155 3DI-185
3
8550 1 1/8 B92 B100 403 412 420 429 437 446 454 463 471 480 488 497 3DI-161 3DI-190
*When selecting 1 H.P. motor, be sure to select Pulley-Belt Kit with same pulley bore as shaft size of motor selected.
SIZING TABLES
OUTDOOR
DRY BULB
TEMP.
3/4 H.P. MOTOR / CFM-SP* 1 H.P. MOTOR / CFM-SP* 1-1/2 H.P. MOTOR / CFM-SP* 2 H.P. MOTOR / CFM-SP* 3 H.P. MOTOR / CFM-SP*
6997 / 0 4415 / .5 1571 /1.0 7702 / 0 5477 / .5 2609 /1.0 8817 / 0 6961 / .5 4425 / 1.0 9375 /.1 8043 / .5 5932 / 1.0 9377 / .6 8046 / 1.0
OUTDOOR WET-BULB OUTDOOR WET-BULB OUTDOOR WET-BULB OUTDOOR WET-BULB OUTDOOR WET-BULB
75
65 55
75 65 55 75 65 55 75
65 55
75 65 55 75 65 55 75
65 55
75 65 55 75 65 55 75
65 55
75 65 55 75 65 55 75
65 55
75 65 55 75 65 55
85
LAT
GPH
76
8
67
15
58
23
76
4
67
9
58
13
76
2
66
4
56
5
77
8
67
16
58
25
76
6
67
12
58
18
76
3
66
6
57
9
76
9
67
19
59
28
76
7
67
15
58
22
76
5
67
10
58
15
76
10
67
20
59
30
76
9
67
17
58
26
76
6
67
13
58
19
–
–
–
–
–
–
76
10
67
20
59
30
76
9
67
17
58
26
95
LAT
GPH
77
15
68
23
59
30
77
10
68
14
59
19
76
4
66
5
56
7
77
16
68
25
60
33
77
12
68
18
59
24
76
6
67
9
58
12
77
19
68
28
60
37
77
15
68
22
59
30
77
10
68
15
59
19
77
20
69
30
60
41
77
17
68
26
60
34
77
13
68
19
59
26
–
–
–
–
–
–
77
20
69
30
60
41
77
17
68
26
60
34
105
LAT
GPH
78
23
69
30
–
–
78
14
69
19
–
–
76
5
66
7
–
–
78
25
70
33
–
–
78
18
69
24
–
–
78
9
68
12
–
–
79
28
70
37
–
–
78
22
69
30
–
–
78
15
69
19
–
–
79
30
70
41
–
–
78
26
70
34
–
–
78
19
69
26
–
–
–
–
–
–
–
–
79
30
70
41
–
–
78
26
70
34
–
–
115
LAT
GPH
79
30
70
38
–
–
79
19
70
24
–
–
76
7
67
9
–
–
80
33
71
41
–
–
79
24
70
30
–
–
78
12
68
15
–
–
80
37
71
47
–
–
79
30
70
37
–
–
79
19
70
24
–
–
80
41
17
51
–
–
80
34
71
43
–
–
79
26
70
32
–
–
–
–
–
–
–
–
80
41
71
51
–
–
80
34
71
43
–
–
*Static pressure (inches of water). GPH = water consumption at design conditions but does not include bleed-off amount. Amount of bleed-off will vary with different water sources, but an
amount equal to 10% of water consumption at any design condition suffi cient for average water. LAT=Cooler Discharge Temperature.
COMMERICAL SPECIFICATIONS GUIDE
Series SAS/SAD 15012
Q
D
E
E
A
F
G
X
D
S
Q
D
C
R
C
N
B
A
E
E
N
T
W
H
U
BP
W
J
L
Y
M
J
SAD OUTLETSAD OUTLET
SAS
OUTLET
TOP VIEW
WEIV EDISWEIV TNORF