MINI ID R134a REFRIGERANT ANALYZER PART NUMBER: 69134-A OPERATION MANUAL Manual Part Number: 5-06-4900-62-1 Manual File MN-A-0201 Rev. A Mini ID Mastercool Inc.
The terms of these warranty provisions shall apply to all products sold by Mastercool Inc., except filters which are considered “consumable items,” and as such are not covered by the terms of these warranties. No waiver, alteration or modification of the terms of these provisions shall be valid unless in writing and signed by an executive officer of Mastercool Inc.. EXCEPT AS SPECIFICALLY SET FORTH AND LIMITED IN THIS PARAGRAPH, MASTERCOOL INC., INC.
MASTERCOOL INC. warrants, subject to the terms listed below, that the goods will be free from defects in design, materials, and workmanship for a period of (1) one year from the date that the goods are shipped to the buyer. THE SOLE LIABILITY OF OF MASTERCOOL INC. FOR ALL PURPOSES SHALL BE TO REREPAIR OR REPLACE, AT THE SOLE OPTION OF MASTERCOOL MASTERCOOL INC. , DEFECTS DEFECTS APPEARING WITHIN THE (1) ONE YEAR PERIOD. MASTERCOOL MASTERCOOL INC.
Table of Contents SPECIFICATIONS For Your Safety………………………………………………………………….. Refrigerant Detected: R134a Pass/Fail Purity: 95% Power: 12—15 VDC @ 1 amp Sample Source: Oil Free Vapor Refrigerant Minimum Input Pressure: 1.38 Bar (20 Psig) 3 General Cautions………………………………………………………………. 3 Welcome…………………………………………………………………………… 5 Introduction………………………………………………………………………. 6 Maximum Input Pressure: 20.
HELP / TROUBLESHOOTING For Your Safety: Unit Fails to Power On - Check the voltage and polarity of the power source. Ensure that the power plug is fully inserted into the power socket on the unit. Excess Air / Fail—The Mini ID is equipped with a unique filter located be- PLEASE READ THIS MANUAL IN ITS ENTIRETY BEFORE ATTEMPTING INSTALLATION OR OPERATION! Attempting to operate the Mini ID without fully understanding its features and functions may result in unsafe conditions. tween the coupler and hose.
• • • • • • • • • • • • • • Always wear eye and skin protection when working with refrigerants. Escaping refrigerant vapors will present a freezing danger. To reduce the risk of electrical shock, do not disassemble the instrument; do not use the instrument in wet or damp areas. DO NOT direct refrigerant vapors venting from hoses towards the skin. DO NOT disassemble the instrument. There are no serviceable components internal to the instrument and disassembly will void the warranty.
PRODUCT COMPONENTS WELCOME Thank you for purchasing the MINI ID R134a Refrigerant Analyzer. Neutronics to insert photo of unit upon receiving Mastercool labels. The Mini ID is the most economical refrigerant identifier ever designed for analysing the purity of gaseous R134a automotive refrigerant. It has many features to offer the user, which will be described in this manual. We recommend that all personnel who use this instrument read this manual to become more familiar with its proper operation.
INTRODUCTION AND OVERVIEW PRODUCT DESCRIPTION Contamination of refrigerants in vehicle air conditioning systems can lead to component corrosion, elevated head pressures and system failures when utilized by unsuspecting technicians. The ability of the technician to determine refrigerant type and purity is severely hampered by the presence of air when attempting to utilize temperature-pressure relations.