Dateinformationencodedintimecode
Checkthisoptionifthetimecodesourceencodesdateinformation.ForSMPTEtypetimecodes,the
datemustbeencodedtotheLeitch
TM
specification.ForIRIGBtimecode,thedatemustbeencoded
withintheIEEE1344specification.[Note:datesupportforIRIGBunderIEEE1344requiresTCR500
timecodereaderfirmwareversion1.6orlater,orTCR500PCIcard.ConsultTCR500manualfor
informationondeterminingfirmwareversion.]
Time/Dateintimecodeisadjustedfordaylightsavingstime(duringDST)
Checkthisoptionifyourtimecode,time/dateinformationisadjustedfordaylightsavingstime
(duringDST)tosometimezonestandard.Thisoptionisavailableonlyiftheselected time zone
referencedefinesdaylightsavingstimeandtheDateinformationencodedintimecodeoptionis
checked.
Selecttimezone
CheckUTCifyourincomingtimecodeisreferencedtoUTC/GMT,selectOtherifitisnot.IfOtheris
selectedatimezonemustbechosenfromthetimezonelistbox.Selectthetimezonethatmatches
thereferenceofyourtimecodesource.Thisisnotnecessarilyyourlocaltimezone.Iftheselected
timezonedefinesdaylightsavingstime,thestartandendofdaylightsavingstimewillbedisplayed
belowthetimezoneselectionlistbox.Youmayselectatimezonethatdefinesdaylightsavingstime
evenifyourtimecodesourcedoesnotadjustfordaylightsavingstime.
6.Selectanadditionalpopupnotificationto
indicatedtimecodelossinexcessof3minutes.
7.Tosavetheconfigurationsettings,click
[Apply].
WindowsOSdoesnothavetorestartinorderforchangestotakeeffect.