Masterclock Product Catalog 2012-2013
Master Clock Overview Multifunctional vs.
Multi-Functional Master Clock MCR 1000 Reference Options • GPS (atomic clock) • NTP • Time Code • High Stability Oscillator • NMEA 0183 • NENA 911 PSAP Standard Output Options • NTP • Time Code • Truetime/Kinemetrics • NMEA 0183 • NENA 911 PSAP Standard • PPO • PPS • 10MHz sine wave The MCR1000 Master Clock Reference system is a compact, precision time and frequency device. One unit can reference and output NTP, Time Code and a 10 MHz sine wave all locked to the atomic clocks in GPS satellites.
Master Clock Upgrades MCR Modules and Add-In Options STANDARD MCR FEATURES Manual time set via network and USB NENA In/Out (Format 0, 1 and 8) NMEA 0183 In (ZDA, GGA, GLL, RMC) NMEA 0183 Out (ZDA) NTP Input client software PPS Relay programmable ‐ 1 event RS232 Port TCXO oscillator ± 1 min/year TELNET network setup software Time/Date data output via USB USB Port Windows USB setup software Windows network setup software ADD‐IN FEATURES Modules (M) ‐ Module, (F) ‐ Firmware, (S) ‐ Software GPS (M) Catalog P
Master Clock Upgrades MCR-GPS Module Option Key Features • • • • • • • • • Add to MCR1000 or MCR5000 Receives time signals from up to twelve GPS satellites Provides accurate reference to within ± 100 nS of UTC Optional NMEA‐0183 messages on serial port output Provides most accurate external time source for MCR Includes Standard Antenna Antenna cable lengths up to 500’ (152 m) available In‐line surge arrestors and in‐line GPS amplifiers available Compact design for portable applications Masterclock’s MCR
Master Clock Upgrades MCR-TCR Module Options Key Features • Add to MCR1000 or MCR5000 • Reads and synchronizes to SMPTE and IRIG Time Codes • Software controlled • Advanced TCR option available • Autodetect and automatic gain control of incoming Time Code • Optional interconnects with BNC9 female adapter, terminal block adapter (MCR1000) or BNC female, 3 POS terminal block (MCR5000) Masterclock’s MCR‐TCR (Time Code Reader) is an add‐in module option for master clock reference devices that reads and synchro
Master Clock Upgrades MCR-TCG Module Option Key Features • Add to MCR1000 or MCR5000 • Generates SMPTE and IRIG‐B time codes, plus optional IRIG‐A and ‐E • Locks to GPS Receiver, Time Code Reader, NTP Client and HSO • Optional Interconnects with BNC9 female adapter, Terminal Block adapter (MCR1000) BNC female, 3 POS Terminal Block (MCR5000) Masterclock’s MCR‐TCG (Time Code Generator) is an add‐in module option for master clock reference devices that generates SMPTE or IRIG‐B time code signals.
Master Clock Upgrades NMEA Input/Output Firmware Option Key Features • Add to MCR1000 and MCR5000 • Reads, synchronizes to and outputs from NMEA‐0183 ASCII messages • Transmitted over RS‐232, Ethernet and USB ports • Software controlled • Supports baud rates from 4,800 to 57,600 Masterclock’s MCR‐NMEA is an add‐in firmware option for master clock reference devices that reads, synchronizes and outputs NMEA‐0183 messages.
Master Clock Upgrades MCR-HSO Module Options Key Features • Add to MCR1000 or MCR5000 • Available in three precision grade levels (see chart) • Typical holdover stability of 1 ppb/day, or better with OCXO • Optional 10MHz frequency reference output • Locks to most accurate time source (GPS Receiver, Time Code Reader, NTP Client) • Optional 10MHz reference output Masterclock’s MCR‐HSO (High Stability Oscillator) is an add‐in module for master clock reference devices.
Master Clock Upgrades MCR-PPO Module Option Key Features • Add to MCR1000 and MCR5000 • User programmable pulse width of .0001 to 214,747 seconds (2.
Multi-Functional Master Clock MCR 5000 6 Digit (above) MCR5000 Display Modules 12 Digit (below) Reference Options Precision Time and Frequency Reference System • GPS • NTP • Time Code • High Stability Oscillator • NMEA 0183 • NENA 911 PSAP Standard The MCR5000 Master Clock Reference system is a 1RU rack mount, precision time and frequency device. It’s larger than the MCR1000 and can handle more modules.
Master Clock Upgrades MCR Modules and Add-In Options STANDARD MCR FEATURES Manual time set via network and USB NENA In/Out (Format 0, 1 and 8) NMEA 0183 In (ZDA, GGA, GLL, RMC) NMEA 0183 Out (ZDA) NTP Input client software PPS Relay programmable ‐ 1 event RS232 Port TCXO oscillator ± 1 min/year TELNET network setup software Time/Date data output via USB USB Port Windows USB setup software Windows network setup software ADD‐IN FEATURES Modules (M) ‐ Module, (F) ‐ Firmware, (S) ‐ Software GPS (M) Catalog P
Master Clock Upgrades MCR-GPS Module Option Key Features • • • • • • • • • Add to MCR1000 or MCR5000 Receives time signals from up to twelve GPS satellites Provides accurate reference to within ± 100 nS of UTC Optional NMEA‐0183 messages on serial port output Provides most accurate external time source for MCR Includes Standard Antenna Antenna cable lengths up to 500’ (152 m) available In‐line surge arrestors and in‐line GPS amplifiers available Compact design for portable applications Masterclock’s MCR
Master Clock Upgrades MCR-TCR Module Options Key Features • Add to MCR1000 or MCR5000 • Reads and synchronizes to SMPTE and IRIG Time Codes • Software controlled • Advanced TCR option available • Autodetect and automatic gain control of incoming Time Code • Optional interconnects with BNC9 female adapter, terminal block adapter (MCR1000) or BNC female, 3 POS terminal block (MCR5000) Masterclock’s MCR‐TCR (Time Code Reader) is an add‐in module option for master clock reference devices that reads and synchro
Master Clock Upgrades MCR-TCG Module Option Key Features • Add to MCR1000 or MCR5000 • Generates SMPTE and IRIG‐B time codes, plus optional IRIG‐A and ‐E • Locks to GPS Receiver, Time Code Reader, NTP Client and HSO • Optional Interconnects with BNC9 female adapter, Terminal Block adapter (MCR1000) BNC female, 3 POS Terminal Block (MCR5000) Masterclock’s MCR‐TCG (Time Code Generator) is an add‐in module option for master clock reference devices that generates SMPTE or IRIG‐B time code signals.
Master Clock Upgrades NMEA Input/Output Firmware Option Key Features • Add to MCR1000 and MCR5000 • Reads, synchronizes to and outputs from NMEA‐0183 ASCII messages • Transmitted over RS‐232, Ethernet and USB ports • Software controlled • Supports baud rates from 4,800 to 57,600 Masterclock’s MCR‐NMEA is an add‐in firmware option for master clock reference devices that reads, synchronizes and outputs NMEA‐0183 messages.
Master Clock Upgrades MCR-HSO Module Options Key Features • Add to MCR1000 or MCR5000 • Available in three precision grade levels (see chart) • Typical holdover stability of 1 ppb/day, or better with OCXO • Optional 10MHz frequency reference output • Locks to most accurate time source (GPS Receiver, Time Code Reader, NTP Client) • Optional 10MHz reference output Masterclock’s MCR‐HSO (High Stability Oscillator) is an add‐in module for master clock reference devices.
Master Clock Upgrades MCR-PPO Module Option Key Features • Add to MCR1000 and MCR5000 • User programmable pulse width of .0001 to 214,747 seconds (2.
Master Clock Upgrades Digit Display Options and Event Time Basic Choose from MCR1000 six‐ and nine‐digit models Choose from MCR5000 six‐ and twelve‐digit models Event Time Basic MCR Event Time Basic is a Windows® application that allows a user to create a schedule for the activation of the relay switches in the MCR1000 and MCR5000. • • It is highly configurable, allowing a user to do all of this: • • • • • • • • Define several sequences of on/off states for the relay.
Master Clock Upgrades Digit Display Options and Event Time Basic Choose from MCR1000 six‐ and nine‐digit models Choose from MCR5000 six‐ and twelve‐digit models Event Time Basic MCR Event Time Basic is a Windows® application that allows a user to create a schedule for the activation of the relay switches in the MCR1000 and MCR5000. • • It is highly configurable, allowing a user to do all of this: • • • • • • • • Define several sequences of on/off states for the relay.
Dedicated Master Clocks NTP100-GPS-HS FEATURES • • • • • • • NTP reference for Ethernet LANs in self‐contained box Time synchronized to atomic clock in GPS satellites providing Stratum 1 accuracy Typical holdover stability of 1ppb/day (<7 sec/year) using high precision internal OCXO during GPS loss.
Dedicated Master Clocks NTP100-OSC FEATURES • • • • • NTP reference for Ethernet LANs in self‐contained box Time synchronized to internal precision temperature compensated crystal oscillator (TXCO) NTP query (Unicast), Multicast or Broadcast modes Assignable network configuration Telnet or serial interface – WinDiscovery control included SPECIFICATIONS NTP Time Accuracy • After initial input of time setting the NTP100‐OSC will typically maintain accuracy of ± 1min/year or < 165ms per day using an interna
Dedicated Master Clocks NTP100-OSC-HS FEATURES • • • • • NTP reference for Ethernet LANs in self‐contained box NTP time synchronized to an internal precision oven controlled crystal oscillator (OXCO) for typical stability of 1 ppb/day (< 7 sec/year) after 30 days of aging.
Dedicated Master Clocks NTP100-TC FEATURES • • • • • NTP reference for Ethernet LANs in self‐contained box Time synchronized to your existing IRIG or SMPTE time code source NTP query (Unicast), Multicast or Broadcast modes Assignable network configuration Telnet or serial interface – WinDiscovery control included Rack mountable with an RM4 SPECIFICATIONS Time Reference NTP Time Accuracy • Supports DHCP/BOOTP for automatic acquisition of • When synchronized to external time code source – long network ad
GPS Referred Master Clock GPS500 FEATURES • • • • • • Generates SMPTE / EBU or IRIG‐B Time Codes Synchronized to atomic clocks in GPS satellites ‐11.
Time Code Oscillator Model # TCO-100 FEATURES • Generates SMPTE, EBU, 30, 25 and 24 fps or IRIG‐B (modulated and unmodulated) Time Codes • Functions as a backup Time Code source for master clock systems • Can be connected to a GPS‐500 master clock generator to automatically synchronize to GPS atomic clock time. • With loss of signal the TCO‐100 will revert to a highly stable internal crystal oscillator and continue to provide an accurate Time Code output.
Rack Mount Network Time Clock NTDS16 FEATURES • 1” (2.
Rack Mount Network Time Clock NTDS19 FEATURES • • • • • • • • • 1” (2.
Rack Mount Network Time Clock NTDS112 FEATURES • • • • • • • • • 1” (2.
NTP Digital Clock NTDS 24 Dual Face Option FEATURES • • • • • • • • • • • 2.3" (5.
NTP Digital Clock NTDS 26 Wall‐mount bracket ‐or‐ 2U Rack‐mount bracket (specify) FEATURES • • • • • • • • • • • 2.3" (5.
NTP Digital Clock NTDS 29 FEATURES • • • • • • • • • • • • 1.8" (4.
NTP Driven Clock NTDS 44 FEATURES • • • • • • • • • • • 4" (10.
NTP Driven Clock NTDS 46 2.3” seconds option FEATURES • • • • • • • • • • • 4" (10.
NTP Driven Clock NTDS 84 FEATURES • • • • • • • • • • 7" (18 cm), four‐digit LED Display colors available in red, green, amber and blue Syncs to external or internal NTP source for accurate traceable time Display time in 12‐ or 24‐hour format – hh:mm Adjustable brightness All international Time Zones and automatic Daylight Savings Times Wireless network available on special order Standard chassis color is black powder coat PoE, or worldwide AC power CE marked for sale in EU – FCC, Class B, emissions Wall
NTP Driven Clock NTDS 86 FEATURES • • • • • • • • • • • 7" (18 cm), six‐digit LED Display colors available in red, green, amber and blue Syncs to external or internal NTP source for accurate traceable time Display time in 12‐ or 24‐hour format – hh:mm:ss Adjustable brightness; visible from 350 feet (100 meters) All international Time Zones and automatic Daylight Savings Times Wireless network available on special order Standard chassis color is black powder coat PoE, or worldwide AC power CE marked for sa
NTP Digital Clock Display NTDS 4626 FEATURES • • • • • • • • • Time and date display with six 4" (10.2cm) digits on the top row and six ‐ 2.3” (5.
NTP Driven Clocks NTDS4626-3AL Black Powder Coat Chassis Stainless Steel Chassis FEATURES • Large time and date display with six 4" digits (10.2cm), six 2.3” digits (5.8cm) and three alphanumeric 2.3” digits (5.8cm) • Available in any unit combination of red, green, amber or blue.
NTP Driven Clocks Model # NTDS8646-SS FEATURES • Time and date display with six 7" (18cm) digits and six ‐ 4” (10.
NTP Analog Clocks CLKNTD 12 FEATURES • • • • • • • • • • • Uses external (or your own internal) NTP source for accurate time traceable to NIST ‐11.
NTP Analog Clocks CLKNTD 15 FEATURES • • • • • • • • • • • • • 14.9” (37.85cm) analog clock Uses external (or your own internal) NTP source for accurate time traceable to NIST ‐11.
NTP Analog Clocks CLKNTD 18-SS FEATURES • • • • • • • • • • • • • Large 18” (40cm) analog clock Uses external (or your own internal) NTP source for accurate time traceable to NIST ‐11.
NTP Analog Clocks CLKNTD 30 FEATURES • • • • • • • • • • • • • 30” (76cm) burnished stainless steel clock Uses external (or your own internal) NTP source for accurate time traceable to NIST ‐11.
NTP Dual Face Clocks 3.7 SPECS Digital Clocks – 4 Digit NTDS24DF Size: 10.3w x 7h x 3.5d in 25.9w x 17.8h x 8.4d cm Weight: 4 lbs 1.8 kg NTDS44DF Size: 15.75w x 9.5h x 3.5d in 40w x 24h x 9d cm Weight: 8.6 lbs 3.9 kg NTDS84DF Size: 26w x 10h x 4.5d in 66w x 25.4h x 11.4 cm Weight: 11.7 lbs 5.3 kg NTDS26DF Size: 15.5w x 7h x 3.5d in 39.5w x 18h x 9d cm Weight: 6 lbs 2.7 kg TCDS26DF Size: 15.5w x 7h x 3.5d in 39.5w x 18h x 9d cm Weight: 6 lbs 2.7 kg NTDS46DF Size: 25w x 9.5h x 3.
Up/Down Timer Controller Model # RC 500 The RC500 is a remote control that adds count down and count up timer control features to our NTDS and TCDS clocks. Uses WinDiscovery software (included).
Time Code Driven Clocks TCD200 FEATURES • • • • • • • • • • • • Six digits, 0.6 inch (1.5 cm) tall, seven‐segment LEDs available in red, green, blue and amber Syncs to IRIG‐B, SMPTE and EBU (also 24 fps film and drop frame) Time Codes 24‐ or 12‐hour time display – PM indicator Time display: hh:mm:ss Date display: MM:dd:yy ‐ or ‐ dd:MM:yy – internal switch configurable ‐11.
Rack Mount Time Code Clock TCDS16 FEATURES • 1” (2.
Rack Mount Time Code Clock TCDS19 FEATURES • 1” (2.
Rack Mount Time Code Clock TCDS112 FEATURES • 1” (2.
Time Code Driven Clock TCD 24 FEATURES • • • • • • • • • • Four 2.3" (5.8cm), seven‐segment LEDs Display colors available in red, green, amber and blue Syncs to IRIG‐B and SMPTE, EBU non‐drop frame Time Codes Automatic Time Code type detection and input level control Display time in 12‐ or 24‐hr format – hh:mm Display date MM‐dd or dd‐MM Brightness control: 8 levels, switch configurable ‐11.
Time Code Driven Clock TCD 26 FEATURES • 2.3" (5.8cm), 6 digit LED – display colors available in red, green, amber or blue • Syncs to IRIG‐B and SMPTE, EBU non‐drop frame Time Codes • Automatic Time Code type detection and input level control • Display time in 12‐ or 24‐hr format – hh:mm:ss • Display date MM‐dd‐yy or dd‐MM‐yy – switch configurable • Brightness control: 4 levels – switch configurable • ‐11.
Time Code Driven Clock TCDS 26 MOUNTING BRACKETS Features • 2.3” (5.
Time Code Driven Clock TCDS 29 MOUNTING BRACKETS Features • 1.8” (4.
Time Code Driven Clock TCDS 29 MOUNTING BRACKETS Features • 1.8” (4.
Time Code Driven Clock TCD 86 FEATURES • • • • • • • • • • • Six 7.1" (18 cm), seven‐segment LEDs Display colors available in red, green, amber and blue Syncs to IRIG‐B and SMPTE, BU non‐drop frame Time Codes Automatic Time Code type detection and input level control Display time in 12‐ or 24‐hr format – hh:mm Display date MM‐dd or dd‐MM Brightness control: 4 levels, switch configurable ‐11.
Time Code Analog Clocks CLKTCD 12 FEATURES • SMPTE, EBU and IRIG‐B (modulated and unmodulated) Time Code driven • Self‐correcting to non‐drop frame Time Code • ‐11.
Time Code Analog Clocks CLKTCD 15 FEATURES • 14.9” (37.85cm) analog clock • SMPTE, EBU and IRIG‐B (modulated and unmodulated) Time Code driven • Self‐correcting to non‐drop frame Time Code • ‐11.
Time Code Analog Clocks CLKTCD 18 FEATURES • 18” (45cm) analog clock • SMPTE, EBU and IRIG‐B (modulated and unmodulated) Time Code driven • Self‐correcting to non‐drop frame time code • ‐11.
PCIe with Time Code Reference Input PCIe-TCR PCIe‐TCR card references Time Code sources. Accepts time code formats: SMPTE (Non‐Drop Frame), EBU, NDF and IRIG‐B0 and ‐B1 Increase long‐term accuracy and holdover with an HSO (high stability oscillator) option.
PCIe with GPS Reference Model # PCIe-GPS The Masterclock PCIe‐GPS card receives reference time from atomic clocks orbiting in GPS (Global Positioning System) satellites to provide the most accurate time and date information for a Windows PC. See the User Manual for additional GPS information available through API. Increase long‐term accuracy and holdover with a HSO (high stability oscillator) option.
PCIe with Internal Oscillator PCIe-OSC PCIe‐OSC card provides very stable, accurate time and date information for a Windows PC. Configuration options include GPS or Time Code inputs. Increase long‐term accuracy and holdover with an HSO (high stability oscillator) option.
PC Cards MCR-PCI Real Time Clock Card Our master clock reference (MCR) is a PCI card that provides very stable accurate time and date information for a Windows PC. The card uses a Real Time Clock (RTC) chip and oscillator with temperature compensation to stabilize the PC clock. The MCR maintains PC accuracy to 165 mSec per day, or 1 minute per year. The onboard clock runs from a backup battery in the absence of power from the PC.
Time Code Reader Model # TCR1000 FEATURES • Accepts Time Code formats: SMPTE 24‐fps (Film), 25‐fps (EBU), 30‐fps NDF (Non‐Drop Frame), IRIG‐B0 (unmodulated/pulse width modulated) and IRIG‐B1 (amplitude modulated, 1kHz) • Allows millisecond synchronization accuracy • Automatic Daylight Savings Time and date • TCRSync1000 software that runs as a service providing additional diagnostics and other benefits under Windows XP/7/Server 2003 and 2008‐SP1 • Optional software – TCRSync‐NTP provides NTP refe
Time Code Interface TCC 100P FEATURES • Converts Time Codes to parallel BCD • Reads SMPTE (EBU, film & non‐drop frames) • Reads IRIG‐B • Outputs parallel BCD time information • Output format is directly compatible with Utah Scientific MC‐500 series switchers • 120/240 VAC with supplied external wall mounted power supply or • 12 VDC operation • Power supplies available for most countries Rack mountable with an RM4 SPECIFICATIONS Physical I/O Connections • Input power is 12 VDC via 2.
Time Code Interface TCC 500 FEATURES • Reads SMPTE (including EBU, film & non‐drop frame) and IRIG‐B • Outputs parallel BCD time with 8 digit or one millisecond resolution ─ hh:mm:ss:ms (frames) • 120/240 VAC with supplied external wall mounted power supply or 12‐28 VDC operation. • Power supplies available for most countries throughout the world Rack mountable with an RM4 SPECIFICATIONS I/O Connections • Input power: 12 VDC converted from wall mount AC unit 115/230, 50/60 Hz • 2.
Time Code Interface TCI 232 FEATURES • Reads SMPTE and EBU Time Codes • ‐11 to +12 hour selectable Time Zone offsets • Automatic Daylight Savings Time adjustments (selectable) • Time and date information via RS‐232 or RS‐422 • Time mark pulse output (ttl level) at 1 per: second, minute, hour or day • Dry contact closure at 1 per: minute, hour or day • Contact and pulse output can be advanced by 1 second for system re‐sync at 59 second point • Heathkit WWV clock output emulation (for GV switc
Time Code Interface TCI NENA FEATURES • Generates signals for NENA/PSAP equipment • Operate from IRIG‐B or SMPTE Time Code inputs • IRIG‐B modulated or pulse‐width encoded Time Code output • IRIG‐E modulated or pulse‐width encoded Time Code output • All Time Code outputs support signature control • All Time Code outputs encode NENA extensions • Supports NENA‐defined ASCII outputs at 9600, 4800, 2400, and 1200 baud • Perform Time Zone adjustments in display, serial, and Time Code outputs •
Time Code Interface Model # TCA 100 The TCA100 is a Time Code amplifier designed to isolate and strengthen signals in order to distribute them to multiple feeds over large areas.
Time Code, RF & Pulse Amplifier DA12 DA12 SPECS • • • • 2 inputs: 1/12 or 2/6 input/output Output banks are selectable AC or DC coupled Dual isolated output banks Standard chassis color is black powder coat INPUTS ‐ 2 • RF Frequency Level Impedance Isolation A to B 0 Hz – 20 MHz 1 V rms [15 dBm max] 50 Ω or 600 Ω >85 dB • Pulse /DC IRIG Time Code Frequency Level Duty Cycle Impedance • AM IRIG Time Code Frequency Level Modulation Frequency Code Format Impedance 1PPS to 10 MPPS 0‐7V p‐p 0 to 100% 50 Ω o
Time Code Interface Model # The TCS100 is an automatic time code changeover unit designed to provide automatic or manual switching between two time code sources. FEATURES TCS 100 Rack mountable with RM4 • Accepts SMPTE / EBU or IRIG‐B (modulated and unmodulated TC) • Automatically determines TC type and switches to the alternate source if TC is lost or if a problem is detected in the primary TC source.
Bell Ringing System CRL 1000 FEATURES • • • • • • • • • • Four circuit programmable bell controller synchronized to network time (NTP) Industrial or institutional bell ringer system Reference external NTP source or use internal clock with accuracy of ±1 minute per year Executes up to 256 schedule events per day Circuits may be scheduled independently Schedule in 12‐ or 24‐hour format Front panel displays time or date of internal clock and LED indication of relay activation Provides 24VAC, 16 Amps (400VA)
Bell Ringing System Bells FEATURES • • • • • • • • • 6” (150mm) and 10” (250mm) models available Vibrating type bell for general purpose signaling Low power consumption and high decibel rating Use with Masterclock CRL1000 Bell Ringer Controller Mounts on standard 4” square (101mm) electrical box Indoor or outdoor use, ‐40° to 150°F (‐40° to 66°C) (NOTE: outdoor use requires weatherproof mounting electrical box) UL Listed 4 wire termination – 18 AWG stranded Red powdercoat finish Model Bl24‐6 Bl24‐10 Size
Universal Power Supply PSU 45 Combines power needs for an orderly installation of Masterclock equipment. Mounts in RM4 rack‐mount to supply 28V power for up to nine Masterclock rack‐mounted devices.
Power Supplies PSPOE 15 FEATURES • Allows power to be transferred over unused pairs of CAT5 Ethernet cable • Saves on installation cost of wiring power to PoE compliant Ethernet devices • Compliant with IEEE802.
Power Supplies Cisco 8-, 24- and 48-Port PoE Switches Cisco SF302‐08MP – 8 port PoE switch • Standards‐based IEEE 802.3af Power over Ethernet (PoE) ─ Up to 8 ports at 15.4W • Dual gigabit uplinks provide increased bandwidth and redundancy • 802.
GPS Antennas and Mounts Standard and Basic Standard GPS Antenna The standard antenna, coaxial cable and antenna mounting hardware come standard with GPS‐referenced Masterclock equipment packages. The GPS‐based product includes the antenna, coaxial cable with connectors, and antenna mounting. This antenna can be mounted either indoor or outdoor so long as it is exposed to the sky. The antenna was initially designed for external mounting in marine environments.
GPS Antenna Surge Arrestor 10.2 Model # SA90-SMA Broadband Surge Arrestor for DC‐3000 MHz applications Help protect your equipment from the effects of lightning induced surges with the broadband SA90‐SMA Surge Arrestor. This DC‐passing surge arrestor operates with frequencies up to 3 GHz and helps with protection from lightning strikes. The arrestor is compatible with the IEEE 802.11b standard.
Surge Arrestor Installation 102 Model # SA90-SMA Installation: For maximum protection install two surge arrestors, one outside, either close to the antenna or at the point where the coaxial cable enters the building and a second as close to the receiving equipment. A good rule of thumb to remember is that all lines entering or exiting a building need protection. WARNING Ensure that the antenna and coaxial cable that the surge arrestor is protecting is not exposed to direct lightning strikes.
Rack Mount Bracket RM4 Anodized Aluminum Rack Mount Kit provides a sleek, compact, rack ready housing for up to four of our devices. RM4 FEATURES • • • Houses up to 4 Masterclock units Blank panels are supplied for any unused spaces Components can be easily installed or removed in the field SUPPORTED DEVICES • GPS200 • MCR1000 • NTP100 • TCA100 • TCC100 • TCC500 • TCD200 • TCI232 • TCI500 • TCINENA • TCO100 • TCS100 SIZE • • Standard 1RU. 19” x 1 ¾” (48.25 cm x 4.
Information 102 Company History Masterclock, Inc. engineers and builds synchronized digital and analog clocks used by large corporations, universities, sports teams, broadcasters, law enforcement and the military. These clocks maintain their extraordinary precision by receiving signals from GPS satellites circling the Earth and other sources of accurate time. Our Founder William (Bill) Clark (at left in the middle) began building clocks and automation systems for broadcasters in 1986.
Information 102 NTP and Time Code Explained NTP is an open standard Internet protocol that utilizes standard ethernet wiring to synchronize computers, clocks, networks and other systems to a NTP reference server. The signal can be transmitted over LAN and WAN wired networks and over various wireless systems. There are numerous public sources of NTP available. Many universities and governmental agencies provide access to NTP servers.
Information 10.2 Benefits of PoE Power‐over‐Ethernet (PoE) extends the versatility for system designers and companies. No longer will one have to locate access points within the typical six foot electrical cord reach of an AC outlet or look for convenient locations to install new outlets at points where its suitable to run conduit and mount outlet boxes. PoE only requires technicians to run one Ethernet cable – CAT5 or CAT6‐ to the access point for supplying both power and data.
Information 10.2 Domestic Ordering General • We accept VISA and MasterCard credit cards. • We accept purchase orders from firms and institutions with acceptable credit. • Orders can be shipped COD. • We offer a 30‐day satisfaction guarantee on all of our products.
Information 10.2 International Ordering TERMS OF SALES Prices are net US dollars, FOB, our plant. ALL PURCHASE AND CREDIT CARD ORDERS ARE SUBJECT TO ACCEPTANCE.
10.2 Information International Customers Airports Abu Dhabi International Airport Curaçao International Airport Leighton Asia‐Southern Region Airport Macau International Airport Nav Canada Norman Manley International Airport ‐ Jamaica Broadcasting and entertainment Australian Broadcasting BBC Canadian Broadcast Corp Essel Shyam Technologies Ltd EUROCOM Broadcast Gencom Australia Gencom New Zealand Hong Kong Cable TV Ltd.
10.2 Information Domestic Customers Airports General Mitchell Intl Airport Indianapolis Airport Kahului Intl Airport Lambert St. Louis Intl Airport Los Angeles World Airports Raleigh Durham Airport Spirit of St.
10.2 Information Suggested Functional Specs 1.1 SCOPE This document specifies a wired clock system that relies on the accuracy of the Global Positioning Satellite (GPS) system forsynchronizing the time provided to clocks and network devices using the Network Time Protocol (NTP). Such a clock system relies on one or more NTP time servers with an integrated GPS receiver, to act as master clocks and virtually an unlimited number of network clock displays acting as client devices.
2.3.1 NETWORK CLOCK ENGINEERING GENERAL SPECIFICATION The network clocks shall be designed to provide years of reliable and maintenance free service and shall be constructed of all metal enclosures with high impact, UV stable lenses to ensure structural integrity and maximum durability. A wall mounting bracket, or other means, shall be provided for mounting to the surface of a wall.
The gear and drive train system shall be smooth and quiet in operation to minimize motor noise. An LED status indicator on the face of the clock shall illuminate when the clock is not synchronized. The analog clock shall be available with the following options: LED illumination, double face ceiling or wall mount, stainless steel enclosure. 2.3.
Information 10.2 System Operations Time synchronization is more crucial than ever before. It has also never been easier to accomplish. Masterclock provides complete solutions using open standards like NTP (Network Time Protocol) and SMPTE/IRIG Time Code. Just one device can receive atomic clock time and output it to both NTP and Time Masterclock, Inc. Code.
Information 10.2 Product Warranty LIMITED HARDWARE WARRANTY This Masterclock, Inc. (hereinafter Masterclock) product warranty extends to the original purchaser. Masterclock warrants all electronic hardware products against defects in materials and workmanship for a period of one year from date of sale. If Masterclock receives notice of such defects during the warranty period, Masterclock will, at its option, either repair or replace products, which prove to be defective.
Information 10.2 Software Warranty LIMITED SOFTWARE WARRANTY This Masterclock, Inc. (hereinafter Masterclock) product warranty extends to the original purchaser. 30 Day Satisfaction Guarantee For thirty (30) days after date of delivery of the SOFTWARE to you, if you are dissatisfied with the SOFTWARE for any reason you may return the complete product, with your receipt, to Masterclock, postage prepaid, during the thirty (30) day period for a full refund.
Information 10.2 Return Merchandise Policy If you are having a problem with any of our merchandise, a quick call to our service department will typically solve it. Domestic RMA Policy & Form International RMA Policy & Form If you wish to return merchandise, please download and fill out the appropriate RMA (Return Merchandise Authorization) PDF form at left. A Masterclock RMA number is required.
RETURN MERCHANDISE AUTHORIZATION POLICIES AND PROCEDURES Terms ─ Evaluation/Satisfaction Guarantee Return Masterclock, Inc. offers a 30‐day Satisfaction Guarantee on all of our products. If the product does not meet your requirements, return it within 30 days from the invoice date and cancel the Purchase Order or request a refund if the order has been prepaid.
Exchange ─ Refers to returning items to receive different part number: 9. Items that are returned for credit or "change" due to a mistake on customer's part (ordered wrong, end user changed their mind, improper installation, etc.) will be exchanged only after receipt of authorization for payment for 15% of item value with a minimum charge of $50. 10. After 30 days ‐ all sales are final. Filling out RMA Request Form ‐‐ 11. RMA numbers will be issued only with the proper INVOICE NUMBERS. 12.
Masterclock’s RMA Request Form RMA# PLEASE SEE ATTACHED RMA TERMS & CONDITIONS FOR ADDITIONAL DETAILS Date: __________________________________ Company Name: _________________________________ Address 1: ______________________________ Address 2: ______________________________________ City: ___________________________________ State/Country: ________ Contact Person: __________________________ Phone: _______________ Fax: ____________________ Quantity Model # Serial # Zip/Code: _______________ Invoi
CUSTOMER REQUEST FOR CREDIT This is a request for net 30 days credit from date of shipment. We understand and agree that if payment is not received by Masterclock within 30 days of shipment date then a 1.5% charge will be added for each month or part thereof that the payment is late. Please print or type and complete all sections fully.
Masterclock, Inc. 2484 West Clay St. St. Charles, MO 63301 +1-(636)-724-3666 1-800-724-1778 support@masterclock.com sales@masterclock.